18
Compass sit-to-stand
Installation Manual
COMPASS SIT-TO-STAND INSTALLATION MANUAL
Eaton.com/compass
SECTION IV – Operation
A. Cabling the desk
All cables that originate from the desk top should pass
through the rectangular cable grommets in the work
surface, and then through the two cable chain�
Upon exiting the base end of the cable chains, cables may
be routed laterally through the desk structure (for Integrated
type), or through the vertical cable channel (for free standing
desk type), to the floor�
B. Operating the adjustable worksurface
The Compass STS desk uses a DP1U control pad�
NOTICE
Initialize the system
See warnings and instructions on adjacent column
Normal operation
To move the desk up or down press and hold the UP or
DOWN arrow button (/\ or \/) until the desk reaches the
desired height�
Store a memory position
Buttons “1”, “2” and “3” are used to store memory
positions�
•
Press and hold the “S” button
•
Press one of the small buttons with numbers “1”, “2” or
“3” and the position will be stored at this button�
Memory drive
Press and hold one of the memory buttons and the desk
will begin moving to the pre-programmed memory position�
Hold the button until the position is reached�
Up
Down
Memory
1 2 3
Store
Memory
C. Initialize the lift motor systems
WARNING
BEFORE ENERGIZING OR OPERATING THE LIFT
SYSTEM
•
MAKE SURE THAT THE PRECEDING ASSEMBLY STEPS
HAVE BEEN FOLLOWED AND ARE COMPLETED.
•
VERIFY THE CORRECT POSITION OF ALL LIFT MOTOR
CONNECTORS. VERIFY THAT ALL LIFT MOTOR CABLES
ARE PROPERLY SEATED IN THEIR RECEPTACLES.
•
MAKE SURE THAT THE VOLTAGE OF THE CONTROL BOX
IS CORRECT BEFORE THE SYSTEM IS CONNECTED TO THE
MAINS.
To initialize the lift motor system:
1� Temporarily plug the power cord into a nearby AC
electrical outlet per Electrical Ratings��
2� The lift motor system is initialized by pressing and holding
the down button� The motors will automatically lower to
their bottom most position (if not already there), then run
upwards approx� 3 mm, and then down again to their
lowest position� Only release the down button when the
movement has completely stopped�
3� If the button is released before the sequence is
completed then the initialization is interrupted and must
be started again from the beginning�
4� It is sometimes necessary to press the down button
twice to start the initialization� This is because the system
can be in different modes when the initialization starts�
5� After initialization, press the up button to lift the
worksurface support structure about 18 inches in order to
allow access to the underside of the support structure�
WARNING
•
IF THE CONTROL BOX MAKES UNUSUAL NOISE OR
ODORS, IMMEDIATELY UNPLUG THE UNIT FROM THE AC
RECEPTACLE.
•
INSPECT ALL CABLES TO ENSURE THAT THEY ARE NOT
DAMAGED.
•
DO NOT PLUG THE UNIT IN AGAIN. CONTACT
TECHNICAL ASSISTANCE FOR HELP USING THE
CONTACT INFORMATION IN SECTION 1 OF THE
INSTALLATION GUIDE.