background image

18

Compass sit-to-stand

Installation Manual

COMPASS SIT-TO-STAND INSTALLATION MANUAL

         Eaton.com/compass

SECTION IV – Operation 

A. Cabling the desk

All cables that originate from the desk top should pass 

through the rectangular cable grommets in the work 

surface, and then through the two cable chain�
Upon exiting the base end of the cable chains, cables may 

be routed laterally through the desk structure (for Integrated 

type), or through the vertical cable channel (for free standing 

desk type), to the floor�

B. Operating the adjustable worksurface

The Compass STS desk uses a DP1U control pad�

NOTICE

Initialize the system

See warnings and instructions on adjacent column

Normal operation

To move the desk up or down press and hold the UP or 

DOWN arrow button (/\ or \/) until the desk reaches the 

desired height�

Store a memory position

Buttons “1”, “2” and “3” are used to store memory 

positions�

  Press and hold the “S” button

  Press one of the small buttons with numbers “1”, “2” or 

“3” and the position will be stored at this button�

Memory drive

Press and hold one of the memory buttons and the desk 

will begin moving to the pre-programmed memory position� 

Hold the button until the position is reached�

Up

Down

Memory 

1 2 3

Store 

Memory

C.  Initialize the lift motor systems

 

WARNING

 

  

BEFORE ENERGIZING OR OPERATING THE LIFT 
SYSTEM

 

  MAKE SURE THAT THE PRECEDING ASSEMBLY STEPS 

HAVE BEEN FOLLOWED AND ARE COMPLETED.

 

  VERIFY THE CORRECT POSITION OF ALL LIFT MOTOR 

CONNECTORS. VERIFY THAT ALL LIFT MOTOR CABLES 
ARE PROPERLY SEATED IN THEIR RECEPTACLES.

 

  MAKE SURE THAT THE VOLTAGE OF THE CONTROL BOX 

IS CORRECT BEFORE THE SYSTEM IS CONNECTED TO THE 
MAINS.

To initialize the lift motor system:

1�  Temporarily plug the power cord into a nearby AC 

electrical outlet per Electrical Ratings��

2�  The lift motor system is initialized by pressing and holding 

the down button� The motors will automatically lower to 
their bottom most position (if not already there), then run 
upwards approx� 3 mm, and then down again to their 
lowest position� Only release the down button when the 
movement has completely stopped�

3�  If the button is released before the sequence is 

completed then the initialization is interrupted and must 
be started again from the beginning�

4�  It is sometimes necessary to press the down button 

twice to start the initialization� This is because the system 
can be in different modes when the initialization starts�

5�  After initialization, press the up button to lift the 

worksurface support structure about 18 inches in order to 
allow access to the underside of the support structure� 

WARNING

 

  

  IF THE CONTROL BOX MAKES UNUSUAL NOISE OR 

ODORS, IMMEDIATELY UNPLUG THE UNIT FROM THE AC 
RECEPTACLE.

 

  INSPECT ALL CABLES TO ENSURE THAT THEY ARE NOT 

DAMAGED. 

 

  DO NOT PLUG THE UNIT IN AGAIN. CONTACT 

TECHNICAL ASSISTANCE FOR HELP USING THE 
CONTACT INFORMATION IN SECTION 1 OF THE 
INSTALLATION GUIDE.

Summary of Contents for Compass sit-to-stand

Page 1: ...Compass sit to stand Modular Office Furniture Compass sit to stand STS powered adjustable height modular office furniture system Installation manual...

Page 2: ...aton 160 Gold Star Boulevard Worcester MA 01606 Email InfoESWorcesterMA Eaton com Web Visit us at Eaton com CompassSTS and click on Contact Us Complete and submit the form as directed on our website D...

Page 3: ...tions Do not use attachments not recommended by the manufacturer 5 Never operate this furnishing if it has a damaged cord or plug if it is not working properly if it has been dropped or damaged or has...

Page 4: ...mpass furniture desks When it is not possible to attach linear sit to stand desk the maximum allowable organizer wall panel height is 20 Lateral 20 Lb Force Max Organizer wall panel max 20 Linear inte...

Page 5: ...SS SIT TO STAND INSTALLATION MANUAL Eaton com compass SECTION II Parts Identification Free Standing Linear Type Cable Grommet Lift Column Control Box Worksurface Support Control Pad Warning Labels Wor...

Page 6: ...Manual COMPASS SIT TO STAND INSTALLATION MANUAL Eaton com compass Free Standing Corner Type Cable Grommet Lift Column Control Pad Control Box Worksurface Support Warning Labels Worksurface Cable Fill...

Page 7: ...STAND INSTALLATION MANUAL Eaton com compass Integrated Linear Type Cable Grommet Upper Lift Bracket Lift Bracket and Cover Lift Column Control Box Worksurface Support Control Pad Back Panel Stretcher...

Page 8: ...L Eaton com compass Integrated Corner Type Cable Grommet Lift Column Control Pad Filler Strip Back Panel Stretcher Worksurface Support Worksurface Bracket Corner Foot Control Box Worksurface Levelers...

Page 9: ...head screw silver D M6 x 10mm Phillip s head screw black E 8 x 3 4 Phillips flat head wood screw black F 1 4 x 3 4 hex washer head screw black G 1 4 20 x 3 8 button head screw H 8 32 x 1 4 Phillips he...

Page 10: ...ect finished laminate surface from scratches or other possible damage Align the support and bracket if required to the worksurface using the holes pre drilled in worksurface for alignment Secure the s...

Page 11: ...ift columns closest to control box Remove plastic filler strip from worksurface Route cable from lift column through work surface pathway into support and along the stiffener to control box area Repla...

Page 12: ...using 4 M6 x 20 Phillips Head screw C and 5 16 lock washers K per lift Use a 3 Phillips bit Ends of feet will be approximately even with the back edge of worksurface and offset from the front user sid...

Page 13: ...annel tab To retain tab in slot assemble inner channel section over tab attach using 2 20 acorn nuts I Do not tighten Side outer channel down to top of foot aligning tab in outer channel and slot in f...

Page 14: ...ys ensure a sufficient amount of personnel are present during the assembly process Attach legs to existing units if there are any See Compass Installation Guide page 25 for leg connection info For cor...

Page 15: ...bracket cover secured by magnetic fasteners Assemble lift columns to leg assemblies using 3 1 4 20 x hex head screws F each column Check that all parts are properly seated in position and tighten all...

Page 16: ...otor housing No lock washers are used Use a 3 Phillips bit DO NOT TIGHTEN SCREWS NOTICE Start all screws in their holes before tightening NOTE In certain cases some bolts may be difficult to access Th...

Page 17: ...and visually verify to avoid pinching any previously installed cables Secure with 2 1 4 20 locking nut J to stud end Secure with 4 M6 x 10 Phillips head screws D into lift motor housing No lock washer...

Page 18: ...E PRECEDING ASSEMBLY STEPS HAVE BEEN FOLLOWED AND ARE COMPLETED VERIFY THE CORRECT POSITION OF ALL LIFT MOTOR CONNECTORS VERIFY THAT ALL LIFT MOTOR CABLES ARE PROPERLY SEATED IN THEIR RECEPTACLES MAKE...

Page 19: ...ultiple attempts see SECTION IV C for initialization of the lift system If not all of the lift motors respond remove the AC power Disconnect the motor cable both ends of the lift motor that is out of...

Page 20: ...l Every six months Visually inspect the product looking for loose fasteners and loose or damaged parts Inspect all wires and cables looking for loose connections and pinched or frayed wires Laminated...

Reviews: