-40- easyRAID NAS FN-420GT Operation Manual
This page provides tools to configure the easyRAID 420GT to monitor [APC
Back-UPS ES 500(RS232) and Smart series] device.
•
UPS Watch : This radio button group enables/disables UPS watch function of
the system.
•
UPS Selection : The system supports [APC Back-UPS ES 500(RS232) and
Smart series].
•
Time to shutdown : If the UPS watch option is enabled, the default delay of
shutdown is 5 minutes. Otherwise, the system will be shutdown immediately
when a power loss has been detected.
•
Detailed Watch : If this option has been set to "Yes", the system will shutdown
automatically if remaining battery charge falls below 5% on UPS or battery
runtime is below 5 minutes on UPS, which either comes first.
•
Send message to connecting clients : If this option has been set to "Yes", the
system will send message to connecting clients when each power event has
been detected.
•
Update : The system saves all changes if this button is pressed.
•
Cancel : The system skips all the modifications if this button is pressed.
3-4-10 System Firmware Upgrade
The firmware upgrade screen of the system is shown in figure 3-16.
Figure 3-16 Firmware Upgrade
The administrator may acquire the latest version of firmware and save to a local HDD.
By using this menu option, provide the file location to the system and complete
firmware upgrade.
Please contact your local dealer regular to acquire the latest version of firmware.
The file will be in a form that looks like “1.01k-NAS System.bin”. Locate the file using
the Browse button and click “OK”. It will update the firmware automatically and when
completed, the unit will ask you to reboot.