Offset Policy:
If a clock is required showing a later (or earlier) date than
the current one, an offset may be applied. The time which will be printed is
then the current time plus (or minus) the offset. The value of the offset can
be set in three ways:
Fixed offset
A defined offset is applied. Set the offset as shown in
“Offset” below.
The time printed will be the current time plus the fixed
offset.
Prompt offset
The offset to be applied is supplied by the operator.
When the label is sent to the printer, the operator will
be prompted to enter the value of the offset.
The time printed will be the current time plus the
prompted offset.
Pick a date
When the label is sent to the printer, the operator will
be prompted to choose a fixed date. The input screen
offers the choice of Year, Month and Day, displayed in
a calendar format.
The time printed will be the fixed date, in place of the
variable clock.
Certain parts of the prompt can be customised.
(1)
Open the message in the editor.
(2)
Click
Message > Orphaned variables > Edit Variable
and edit the
variable corresponding to the date picker.
Here you can set the text of the prompt and if the last used value is
retained.
Offset:
When a clock is required showing an earlier or later date than the
current one, a fixed offset is entered here. The value entered will determine
how many years, months, days, hours or minutes the clock should skip.
Sub Language:
When another Language is selected, Sub Language
displays the available regional variants of the main Language selected.
Truncate Date:
Clock variable always uses the correct numbers of days
in a specific month.
The Truncate Date settings determine the behaviour when an illegal date
(like 31st of February) is reached.
If Truncate Date is active, the day is set to the maximum day in the specific
month.
If Truncate Date is inactive, the date enters the next month.
Summary of Contents for Compact 32D
Page 1: ...Compact 32d Compact 32C Compact 53c Communicator II Easyprint Product Manual...
Page 2: ...2 25364 Issue 8 March 2018 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 7: ...25364 Issue 8 March 2018 7 EC DECLARATION OF CONFORMITY...
Page 9: ...25364 Issue 8 March 2018 9 EC DECLARATION OF CONFORMITY...
Page 14: ...HEALTH AND SAFETY 1 2 25364 Issue 8 March 2018 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 24: ...DESCRIPTION AND INSTALLATION 2 4 25364 Issue 8 March 2018 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 87: ...DESCRIPTION AND INSTALLATION 25364 Issue 8 March 2018 2 67...
Page 88: ...DESCRIPTION AND INSTALLATION 2 68 25364 Issue 8 March 2018 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 92: ...OPERATION 3 4 25364 Issue 8 March 2018 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 136: ...OPERATION 3 48 25364 Issue 8 March 2018 Line Movement IM Static...
Page 149: ...OPERATION 25364 Issue 8 March 2018 3 61...
Page 150: ...OPERATION 3 62 25364 Issue 8 March 2018 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 228: ...TECHNICAL REFERENCE 5 2 25364 Issue 8 March 2018 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 236: ...TECHNICAL REFERENCE 5 10 25364 Issue 8 March 2018 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 237: ...25364 Issue 8 March 2018 6 1 PART 6 GLOSSARY OF TERMS CONTENTS Page GLOSSARY OF TERMS 6 3...
Page 238: ...GLOSSARY OF TERMS 6 2 25364 Issue 8 March 2018 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 242: ...GLOSSARY OF TERMS 6 6 25364 Issue 8 March 2018 THIS PAGE INTENTIONALLY LEFT BLANK...