background image

 

15

 

 
 
 

 

Warranty 

 

 

 
 
 
THIS WARRANTY IS APPLICABLE TO THE ORIGINAL OWNER ONLY 

In accordance with the warranty terms and conditions specified below 

 

EASY RADIANT “WORKS” 

(the manufacturer) will supply to the 

ORIGINAL 

OWNER. 

A replacement part or any component part which fails before three (3) years  

“NO IF’S AND’S OR BUTS” 

 

SERVICE AND LABOUR RESPONSIBILITY 

 

THE MANUFACTURER WILL PROVIDE ONLY A REPLACEMENT 
HEATER OR PART THEREOF; THE OWNER IS RESPONSIBLE FOR 
ALL OTHER COSTS. 
 

Such cost may include but not limited to: 

 

(a)

 Labour charges for service, removal, or reinstallation of the heater or             

      part thereof. 

(b)

 Shipping and delivery charges for forwarding the new 

“EQUATOR”

    

      or replacement part from 

EASY RADIANT “WORKS

” and returning the     

      claimed defective heater or part to 

EASY RADIANT “WORKS”.

 

(c)

 All costs necessary or incidental for handling and administrative charges       

     and for any materials and/or permits required for installation of the  
     replacement heater or part. 
 
 

 

 
 

EASY RADIANT ”WORKS” 

 

1222 Brawn Road, Wainfleet, Ontario Canada L0S 1V0 

 

Phone: (905) 899 3473 or 1-800 403 EASY (3279) Fax (905) 899 2262 

 

Email [email protected] 

Summary of Contents for HI-30-40P2

Page 1: ...1 This heater may be installed up to a 35 degree angle Installation above a 35 degree angle will voice warranty on the heater...

Page 2: ...W added to the model no indicates wireless model The letter B added to the model no indicates black model The letter S added to the model no indicates stainless steel The letter R added to the model n...

Page 3: ...esult in an improper installation which could result in faulty operation of The Equator causing property damage serious injury or death If you do not fully understand these instructions contact your s...

Page 4: ...hat can be harmful Infrared energy travels by line of sight so the designer must be aware that doors panels or windows may obstruct the infrared energy from reaching the desired location Overlapping i...

Page 5: ...building recesses or inside a soffit Fire sprinkler heads must be located an appropriate distance from The Equator or a sprinkler head with a high enough temperature rating that normal operation of Th...

Page 6: ...ty or mechanical ventilation of the building 2 In conjunction with building ventilation system adequate fresh air into the building must be provided through fresh air inlets and or building openings 3...

Page 7: ...s 3 All gas pipe connections to the heater s must be sealed with a gas pipe compound resistant to liquefied petroleum gases 4 Installation of a drip leg in the gas supply line going to each heater is...

Page 8: ...gle mounted up to 35 degrees maximum When mounting above 20 degrees to a maximum of 35 degrees wind protection must be provided Note clearances to combustibles chart on page 4 Windy conditions can be...

Page 9: ...aters can be placed below a supporting structure with angle mounting The Equator can be installed with up to 35 degree angle to face inward toward each other or outward away from each other Heater Ope...

Page 10: ...an and reinstall 5 Check to insure heater is securely mounted and the clearance from combustible material is maintained 6 If additional service to The Equator is required contact your local representa...

Page 11: ...Plate and Grill Remove Pilot Screen 2 srews COM COM HI M HIGH LOW OFF ON BLUE RED WHITE 36G54 TYP 214 OFF ON RED WHITE 36G22 C Disconnect Wiring From Valve Two Stage Single Stage FS TR GND P MV TH PV...

Page 12: ...12 Removal of the Burner con t E Turn Burner Face Down And Remove 8 Screws And Remove Back Panel F Remove the screws 4 And Lift Burner From Enclosure...

Page 13: ...high resistance check wire connectors c Check spark gap Should be 7 64 109 between electrode tip ground stop If gap is too large spark will occur at wrong location If gap is too small spark may not be...

Page 14: ...ressure improperly sized gas line Variable voltage Wind exceeding 15 mph 24kmh Tip angle exceeding 30 degrees Debris inside burner Erratic winds Deterioration of the Front Grill The Equator must be in...

Page 15: ...OTHER COSTS Such cost may include but not limited to a Labour charges for service removal or reinstallation of the heater or part thereof b Shipping and delivery charges for forwarding the new EQUATO...

Page 16: ...16 HI ER 100...

Page 17: ...17...

Page 18: ...18...

Page 19: ...19...

Page 20: ...20...

Page 21: ...21...

Page 22: ...22...

Page 23: ...23...

Page 24: ...24...

Page 25: ...y installed ERW R which is directly below the green LED 4 Press and continue to hold in the yellow program button It will flash once 5 While depressing the yellow program button on the ERW R depress a...

Page 26: ...and the grey off button to go to the low input 30 000 BTU Buttons 2 3 4 will be inoperative They can be used to control additional heaters in future The G button will control a group of heaters Always...

Page 27: ...tch to Manual In this position the hand held remote will not operate Multiple 2 8 2 Inputs EQUATOR heaters with On Off High Low hand held remote control Your remote control ERW S ERW R has been pre pr...

Page 28: ...netrable tolocal wildlife debris and buildupsofdus tand dirt The following visual inspectionsshould be made periodicallyto ensure your safetyand continuedenjoymentofyou r appliance Duringthe winter mo...

Reviews: