![Easy Radiant Works HI-30-40P2 Installation & Operating Instructions Manual Download Page 9](http://html1.mh-extra.com/html/easy-radiant-works/hi-30-40p2/hi-30-40p2_installation-and-operating-instructions-manual_3534486009.webp)
9
Typical Patio Layouts
At a mounting height of 10 ft.(3 meters),
“The Equator”
will heat an area
of approximately 14 ft. x 14 ft. or196 sq. ft. (4.2 meters or 18.2 sq. meters)
Conditions vary depending upon outdoor temperatures and wind conditions.
SUPPORTING STRUCTURE
SUPPORTING STRUCTURE
SUPPORTING STRUCTURE
FLOOR
FLOOR
FLOOR
RADIANT HEAT
RADIANT HEAT
RADIANT HEAT
RADIANT HEAT
RADIANT HEAT
RADIANT HEAT
RADIANT HEAT
RADIANT HEAT
RADIANT HEAT
RADIANT HEAT
RADIANT HEAT
RADIANT HEAT
RADIANT HEAT
14FT
4.2 m
21FT
6.4 m
10 ft
3 m
10 ft
3 m
10 ft
3 m
Individual heaters can be placed below a supporting structure with angle
mounting.
“The Equator”
can be installed with up to 35-degree angle to
face inward toward each other or outward & away from each other.
Heater Operation
Upon installation of
“The Equator”
and completion of the gas and
electrical supply line to each heater, follow the steps outlined on the
“Lighting Instruction” plate located on the inside of the control door.
Sequence of Operation
Turn gas and power “ON”. The pilot and burner should light within 4
seconds. A flame sensor will shut off the spark. If the burner does not light
within 15 seconds, the flame sensor will shut “OFF” the gas valve; the unit
will try a relite 3 times. To relight the pilot and burner, shut “OFF” power.
Wait 5 minutes. Turn power back “ON”.