“The Equator”

 is C.S.A. design certified as a non-vented infrared heater 

for outdoor or indoor installation. All units are equipped with direct spark 
ignition and 100% safety shutoff for safety and economy. 
 
The aluminized steel enclosures and aluminium face grill provides 
resistance to wind and rain. The slim design and angle mounting options 
provides versatility to fit almost any patio situation. 
 
The installation of

 

“The Equator”

 

must only be performed by licensed 

technicians, trained and educated in the installation of this type of gas 
appliance. 
 

          WARNING

Improper installation, adjustment,

alteration, service or maintenance can cause property
damage, injury or death. Read the installation, operating
and maintenance instructions thoroughly before
installing or servicing the equipment.

 

 

WARNING 

 

Read this manual completely before first installing or servicing this equipment. 
Failure to read and fully understand this manual may result in an improper 
installation, which could result in faulty operation of  

“The Equator”, 

causing 

property damage, serious injury or death. If you do not fully understand these 
instructions, contact your sales representative or the manufacturer prior to the 
commencement of installation, servicing or maintenance. 

Easy

 

Radiant Works

 

accepts no responsibility for damages whatsoever resulting in improper installation 
of this heater. Improper installation voids all warranties. This manual must remain 
with 

“The

 

Equator”

 at all times.

 

                                               
 
                                                                                                                                                                 
 

 
 
 
 
 
 
 
 
 
 

DANGER: 

For indoor installations, the installation must comply with all local 
and governing codes. Minimum ventilation requirements as 
described on page 7 of this manual (or as governed by applicable 
codes) must be met. Improper ventilation may cause injury or death. 

For Your Safety… IF YOU SMELL GAS 

                                  1.  Open all windows. 
 

 

 

 2.  Do not try to light any appliance. 

 

 

 

 3.  Do not use any electrical switches 

Do not use any telephones in the building.  Immediately call your 
local gas supplier from a neighbour’s, and follow the gas supplier’s 
instructions. If you are unable to reach the gas supplier, 
                              CALL THE FIRE DEPARTMENT!

 

Summary of Contents for HI-30-40P2

Page 1: ...1 This heater may be installed up to a 35 degree angle Installation above a 35 degree angle will voice warranty on the heater...

Page 2: ...W added to the model no indicates wireless model The letter B added to the model no indicates black model The letter S added to the model no indicates stainless steel The letter R added to the model n...

Page 3: ...esult in an improper installation which could result in faulty operation of The Equator causing property damage serious injury or death If you do not fully understand these instructions contact your s...

Page 4: ...hat can be harmful Infrared energy travels by line of sight so the designer must be aware that doors panels or windows may obstruct the infrared energy from reaching the desired location Overlapping i...

Page 5: ...building recesses or inside a soffit Fire sprinkler heads must be located an appropriate distance from The Equator or a sprinkler head with a high enough temperature rating that normal operation of Th...

Page 6: ...ty or mechanical ventilation of the building 2 In conjunction with building ventilation system adequate fresh air into the building must be provided through fresh air inlets and or building openings 3...

Page 7: ...s 3 All gas pipe connections to the heater s must be sealed with a gas pipe compound resistant to liquefied petroleum gases 4 Installation of a drip leg in the gas supply line going to each heater is...

Page 8: ...gle mounted up to 35 degrees maximum When mounting above 20 degrees to a maximum of 35 degrees wind protection must be provided Note clearances to combustibles chart on page 4 Windy conditions can be...

Page 9: ...aters can be placed below a supporting structure with angle mounting The Equator can be installed with up to 35 degree angle to face inward toward each other or outward away from each other Heater Ope...

Page 10: ...an and reinstall 5 Check to insure heater is securely mounted and the clearance from combustible material is maintained 6 If additional service to The Equator is required contact your local representa...

Page 11: ...Plate and Grill Remove Pilot Screen 2 srews COM COM HI M HIGH LOW OFF ON BLUE RED WHITE 36G54 TYP 214 OFF ON RED WHITE 36G22 C Disconnect Wiring From Valve Two Stage Single Stage FS TR GND P MV TH PV...

Page 12: ...12 Removal of the Burner con t E Turn Burner Face Down And Remove 8 Screws And Remove Back Panel F Remove the screws 4 And Lift Burner From Enclosure...

Page 13: ...high resistance check wire connectors c Check spark gap Should be 7 64 109 between electrode tip ground stop If gap is too large spark will occur at wrong location If gap is too small spark may not be...

Page 14: ...ressure improperly sized gas line Variable voltage Wind exceeding 15 mph 24kmh Tip angle exceeding 30 degrees Debris inside burner Erratic winds Deterioration of the Front Grill The Equator must be in...

Page 15: ...OTHER COSTS Such cost may include but not limited to a Labour charges for service removal or reinstallation of the heater or part thereof b Shipping and delivery charges for forwarding the new EQUATO...

Page 16: ...16 HI ER 100...

Page 17: ...17...

Page 18: ...18...

Page 19: ...19...

Page 20: ...20...

Page 21: ...21...

Page 22: ...22...

Page 23: ...23...

Page 24: ...24...

Page 25: ...y installed ERW R which is directly below the green LED 4 Press and continue to hold in the yellow program button It will flash once 5 While depressing the yellow program button on the ERW R depress a...

Page 26: ...and the grey off button to go to the low input 30 000 BTU Buttons 2 3 4 will be inoperative They can be used to control additional heaters in future The G button will control a group of heaters Always...

Page 27: ...tch to Manual In this position the hand held remote will not operate Multiple 2 8 2 Inputs EQUATOR heaters with On Off High Low hand held remote control Your remote control ERW S ERW R has been pre pr...

Page 28: ...netrable tolocal wildlife debris and buildupsofdus tand dirt The following visual inspectionsshould be made periodicallyto ensure your safetyand continuedenjoymentofyou r appliance Duringthe winter mo...

Reviews: