10
Lighting Instructions:
To Start
“The Equator”:
1.
Turn Manual gas valve to “ON” position.
2.
Turn electrical supply “ON”
To Shut Down
:
1.
Turn manual gas valve to “OFF” position.
2.
Turn electrical supply “OFF”.
CAUTION:
If burner fails to ignite, shut down electrical power and wait five (5) minutes
before turning power “ON”.
Maintenance
In order to get the maximum performance from
“The Equator”,
we
recommend the following be performed at least annually. More frequent
service and maintenance may be required if
“The Equator”
is located
within 2,000 feet of a waterfront.
1.
With and air hose regulated to 30 psig, blow off any dust and dirt that
has accumulated around the burner and inside the control
compartment of
“The Equator”.
Proper eye protection required.
2.
From the front of the heater, direct the air hose from a distance of
approximately 12 inches (30.5 cm) over the entire exposed area of
each burner’s ceramics.
3.
Do not insert air hose into the inlet of the burner.
4.
Remove main burner orifice, clean and reinstall.
5.
Check to insure heater is securely mounted and the clearance from
combustible material is maintained.
6.
If additional service to
“The Equator”
is required, contact your
local representative of the factory.
Stainless Steel Heater
Stainless steel does not “rust”, however, air pollution can leave brown
deposits on exterior of
“The Equator”.
We recommend washing the outer stainless steel casing only with a mild
detergent solution and wiping it dry with a soft cloth to bring back the
original shine.
The stainless steel may be expected to permanently darken around the flue
outlet at the top of
“The Equator”
over time with extended use.
Servicing Instructions:
Turn off gas and electrical before attempting any service to this appliance.
“The Equator”
may be serviced by opening door to control compartment.
Cover of control compartment must be removed for servicing by removing
six screws holding cover in place.
The cover must be removed if the gas controls, burner or burner orifice is to
be replaced.
Removal of Direct Spark Ignition Control
Disconnect 24VAC volt wiring from electronic control.
Remove two (2) 8-32 x 1-1/4 screws and nuts holding control in place.
Remove control.