MODE 3: AUTOMATIC OPERATION
Typical application: full cylinders/tanks - Remaining and gross weights are displayable.
1.
An empty scale should read zero. If it does not, press the ZRO (ZERO)
pushbutton. If the ZRO pushbutton is not displayed, access the calibration
mode to zero the scale.
2.
Place a full container on the scale; the GR text will flash.
3.
Adjust gross weight to the correct value by using the UP and DOWN arrow
pushbuttons.
4.
Press the ENT pushbutton; the tare weight will be automatically calculated and
stored in memory. The preset “START” value (configuration parameter Px17) of
remaining chlorine weight will now be displayed.
To enter a new tare weight if the remaining value displayed is incorrect, press and hold PB3
for 3 seconds. The display will change to the TARE weight (TARE flashes). Adjust the tare
weight to the correct value and then press ENT when finished (REM = GROSS – TARE). The
remaining weight will again be displayed.
MODE 4: ADJUSTABLE TARE
Typical application: partially used chlorine cylinders - Remaining, tare, & gross weights are
displayable.
1.
An empty scale should read zero. If it does not, press the ZRO (ZERO)
pushbutton. If the ZRO pushbutton is not displayed, access the calibration
mode to zero the scale.
2.
Place a full container on the scale.
3. The
“GR”
text will flash.
4.
Adjust gross weight to the correct value by using the UP and DOWN arrow
pushbuttons.
5.
Press the ENT pushbutton.
6.
The tare will now be displayed as indicated by the flashing “TR” text.
7.
Adjust tare, as required, by using the UP and DOWN arrow pushbuttons.
8.
Press ENT, the remaining weight will now be displayed.
MODE 5: USER-ADJUSTABLE REMAINING
Typical application: chlorine gas cylinders. - Remaining and gross weights are displayable.
1.
An empty scale should read zero. If it does not, press the ZRO (ZERO)
pushbutton. If the ZRO pushbutton is not displayed, access the calibration
mode to zero the scale.
2.
Place a full container on the scale.
3.
“REMAIN” LED will light.
4.
Use the UP and DOWN ARROW pushbuttons to adjust the remaining weight
displayed.
5.
The SELECT pushbutton will toggle display between gross and remaining
weights.