SUMMATION FUNCTION
The EI-4000 has the ability to sum all of the scales connected to the meter (up to four) as well
as four additional scales, which are connected to another EI-4000.
NOTE: The parameters below are only set on the master indicator. The slave indicator
must have P990 set to NO. The sum cannot be viewed on the slave indicator.
P990 SUM CH (sum all channels)
YES: Sum all active scale inputs.
NO: Scale inputs are not summed.
P991 SUM SEL (sum selection)
RE: Remaining weights are summed.
Gr: Gross weights are summed.
P992 SUM EXT (sum external EI-4000).
YES: Sum all active scales. Up to eight scales are summed and displayed.
NO: External (slave) EI-4000 is not present.
VIEWING THE SUMMED WEIGHT
To view the summed weight, from the main weight screens, press
MNU, NEXT, and then SUM.
MASTER/SLAVE EI-4000 CONNECTIONS & CONFIGURATION
Master indicator: P990 = YES, P991 = don’t care, P992 = YES, and P701 = 9600.
ator: P990 = NO and P701 = 9600.
Connections are below (connect C to C, R to T, & T to R):
Slave indic
S:REM 9000 lb