P600 Analog output type selection
Analog output: rE (remaining weight), Gr (gross weight) , Gt
(gross total – sum of all active channels), and nt (remaining total
– sum of all active channels). This selects the weight that is
transmitted via the 4-20mA analog outputs.
P610 Analog output 20mA (full-scale) weight for channel 1
P620 Analog output 20mA (full-scale) weight for channel 2
P630 Analog output 20mA (full-scale) weight for channel 3
P640 Analog output 20mA (full-scale) weight for channel 4
A 20mA analog signal is transmitted when the weight is equal to the value set by the above
parameters. A current of 4mA is transmitted when the weight, selected by P600, is equal to or
less than zero. The analog outputs do not go below 4mA or above 20mA under normal
operation.
P650 4-20mA clip
NO
: will allow the mA output to proportionally fall below 4mA (0 lb/kg) or rise above
20mA until hardware limits are reached.
YES
: will limit the analog output to the 4mA to 20mA range.
SERIAL INTERFACE PARAMETERS
P600 AOUT Gr
NXT LAST ADJ ESC
P610 A-FS 150.0
NXT LAST ADJ ESC
RS232 and RS485 serial interface control parameter(s):
Note: See the section labeled SERIAL COMMANDS for more information.
P700 serial mode (basic/RTU)
BAS
: BASIC serial protocol: RS-232 only
RTU
: MODBUS serial protocol: RS-485 or RS-232
(see
end of manual for register list)
P701 Baud Rate
Select the serial port baud rate (default = 9600). The selections are 300, 600, 1200, 2400,
4800, 9600, 19200 (19.2K), 38400 (38.4k) baud.
P702 data size
Set the number of data bits transmitted. Note: MODBUS requires this parameter to be set to
eight. Choices are 7 data bits & 8 data bits.
P703 stop bits
Set the number of stop bits transmitted. Choices are 1 and 2.
P704 parity
Set the parity bit type, if any. Choices are none, even or odd.
P705 RTU node
Set the MODBUS RTU node. The range is from 2 to 32.
P700 MODE RTU
NXT LAST ADJ ESC