![background image](http://html.mh-extra.com/html/e-mu/eii/eii_owners-manual_518543185.webp)
SEQUENCER MODULE
© 1985, 1986, 1987 E-mu Systems, Inc. Page 185
3. Slider B selects one of the following metronome values:
1/4
quarter note
1/4 t quarter note triplet
1/8
eighth note
1/8 t eighth note triplet
1/16 sixteenth note
1/16 t sixteenth note triplet
click A 24 pulses-per-quarter note click track is send from the MET OUT jack.
4. To continue with the setup process, select the next function (SEQUENCER
SETUP 4). To return to the Module Identifier, press ENTER.
SETUP 4 - Function: CUE
This function lets you cue (monitor) any or all of the tracks recorded in the
Sequencer.
1. With the SETUP sub-module active, key in 4. If you have not yet recorded any
tracks, the display says:
Tracks:
Cue On:
As you record tracks, the track number appears on the top line and an asterisk
appears below each recorded track on the bottom line. For example, if you have
recorded on tracks 3, 4, 5, and 8, the display shows:
Tracks: 3 4 5 8
Cue On: * * * *
2. To turn off a track, press the track number on the keypad; the asterisk will
disappear. To turn the track back on again, press the track number on the
keypad; the asterisk will reappear.
3. To continue with the setup process, press ENTER to return to the Module
Identifier, then select the next function (SEQUENCER SETUP 5).
Hint:
When using the Sequencer for live performance, cue can be used to turn
“alternate” tracks on and off. For example, you could record two or three different
solos on different tracks, and cue up a different solo for each set so that fans who
see the band a lot won’t hear the same solo night after night.
Summary of Contents for EII+
Page 11: ...INTRODUCTION 1985 1986 1987 E mu Systems Inc Page 11 INTRODUCTION ...
Page 20: ...INTRODUCTION 1985 1986 1987 E mu Systems Inc Page 20 ...
Page 26: ...THE GUIDED TOURS 1985 1986 1987 E mu Systems Inc Page 26 THE GUIDED TOURS ...
Page 84: ...VOICE DEFINITION MODULE 1985 1986 1987 E mu Systems Inc Page 84 Fig VDEF 8 Fig VDEF 9 ...
Page 118: ...PRESET DEFINITION MODULE 1985 1986 1987 E mu Systems Inc Page 118 ...
Page 168: ...ENTER MODULE 1985 1986 1987 E mu Systems Inc Page 168 ENTER MODULE ...
Page 214: ...SMPTE SUPPLEMENT 1985 1986 1987 E mu Systems Inc Page 214 SMPTE SUPPLEMENT OVERVIEW PROTOCOL ...