ATC770 Microprocessor-Based Pressure/Process Controller
63
Group 4
Function
Sec.
As Set
LINE.F
Line Frequency
5.3.6
DEFLT
Loading Default Data
5.2.3
Group 5
Function
Sec.
As Set
PI.TYP
Primary Input Selection
6.1.1
RI.TYP
Remote Set Point Input Selection
5.4.1
CO.TYP
Control Output Selection
6.4.1
RO.TYP
Retransmission Output Selection
6.3.1
DEFLT
Loading Default Data
5.2.3
Group 9
Function
Sec.
As Set
AT.TO
Process Time Delay
7.3.8
AT.TAU
Process Time Constant
7.3.8
AT.KP
Process Gain
7.3.8
AT.TI
Start Time of Start Function
7.3.8
AT.T2
Stop Time of Start Function
7.3.8
Enter your individual settings in the As Set column.
11.1
G
ROUP
1 P
ARAMETERS
SET POINT - Group 1
Available:
Always
Upper display: Set point value
Lower display: SP
Range:
From SP.LO to SP. HI.
ALARMS MASK RESET - Group 1
Available:
Only if one or more alarms are configured with mask at start-up
Upper display: OFF
Lower display: AL.MSK
Range:
Use the
▲
and
▼
keys to switch the upper display from OFF to RESET, then press
the FUNC key to restore the alarm mask.
Default value:
not applicable
SECURITY - Group 1
Available:
Only if CODE.A or CODE.B or CODE.C are On.
Upper display: A b C or A b C. or A b. C or A. B. C. One or more digits followed by a decimal
point means that the access to modification of the parameters of the related security
level is inhibited.
Lower display: SECUR
Range:
Use
▲
and
▼
keys to input the security code; if the selected code matches the
programmed code the parameters of the related security level are unlocked. The
Summary of Contents for ATC770
Page 19: ...ATC770 Microprocessor Based Pressure Process Controller 19 Fig 2 ATC770 Outline Drawing...
Page 23: ......
Page 30: ...30 Fig 6 Remote Set Point Jumper Location Board E...
Page 84: ...NOTES...
Page 85: ...NOTES...
Page 86: ...NOTES...
Page 88: ...DYNISCO INSTRUMENTS 38 FORGE PARKWAY FRANKLIN MA 02038 ATTN MARKETING DEPT Place Stamp Here...