ATC770 Microprocessor-Based Pressure/Process Controller
5
•
Return to GROUP none and observe that the value in the upper display is the actual setpoint
you wish to control.
•
When the SMART LED has stopped flashing, press and hold the A/M key for at least 5 seconds.
The manual LED will extinguish, and you will be automatic control mode.
•
Again, return to GROUP 2 and select SMART. Turn the function on with the up arrow, and enter
with the FUNC. This will activate the Adaptive Tune algorithm, and will maintain the correct
P&I(D) parameters for the process. It will remain on until manually turned off. It will also come
on anytime the ATC770 is the automatic control mode.
•
Return to Group none, and observe the process. The setpoint may be adjusted in GROUP 1
while the controller is in automatic mode.
•
Operator may alternately display Output %, Set Point, Deviation, Peak Value, or RPM by
pressing the up arrow key.
The preceding Quick Start instructions are the basic settings required to install, wire, and get the
controller operating. Please refer to the complete installation and operation manual for additional
functions. Questions on your transducer will be addressed in the manual included with your
transducer.