Maintenance - 2000h
4812165301.pdf
2022-09-02
3
6
4
5
2
Fig. Air cleaner
1. Clips
2. Cover
3. Main filter
4. Backup filter
5. Filter housing
6. Dust valve
1
Release the clips (1), pull off the cover (2),
and pull out the main filter (3).
Do not remove the backup filter (4).
Clean the air cleaner if necessary.
See section Air cleaner - Cleaning.
When replacing the main filter (3), insert a new filter
and refit the air cleaner in the reverse order.
Check the condition of the dust valve (6).
Replace if necessary.
When refitting the cover, make sure that the dust valve
is positioned downwards.
Backup filter - Change
Fig. Air filter
1. Backup filter
1
Change the backup filter with a new filter after every
second replacement of the main filter.
To change the backup filter (1), pull the old filter out of
its holder, insert a new filter and reassemble the air
cleaner in the reverse order.
Clean the air cleaner if necessary, see section Air
cleaner - Cleaning.
155
Summary of Contents for CA3500DCP
Page 2: ......
Page 22: ...Safety Optional 4812165301 pdf 2022 09 02 10...
Page 26: ...Special instructions 4812165301 pdf 2022 09 02 14...
Page 36: ...Technical specifications 4812165301 pdf 2022 09 02 24...
Page 45: ...Machine description 4812165301 pdf 2022 09 02 4812129673 Warning CALIFORNIA Proposition 65 33...
Page 112: ...Operating instructions Summary 4812165301 pdf 2022 09 02 100...
Page 114: ...Preventive maintenance 4812165301 pdf 2022 09 02 102...
Page 124: ...Maintenance Maintenance schedule 4812165301 pdf 2022 09 02 112...
Page 178: ...Dynapac Compaction Equipment AB Box 504 SE 371 23 Karlskrona Sweden www dynapac com...