Maintenance - 500h
ICA270-IN2EN1.pdf
2012-11-05
Fuel pre-filter - Replacement
Fig. Engine compartment
1. Fuel prefilter
2. Hose clamps (2 pcs.)
1
2
Ensure good ventilation (air extraction) if the
diesel engine is run indoors. Risk of carbon
monoxide poisoning.
Ensure good ventilation (air extraction) if the
diesel engine is run indoors. Risk of carbon
monoxide poisoning.
Loosen the hose clamps (2) and remove the pre-filter
(1). Fit the new filter, taking care to fit in the direction
of flow.
Discard the pre-filter (1) in a safe manner, its of
expendable type and can not be cleaned.
Discard the pre-filter (1) in a safe manner, its of
expendable type and can not be cleaned.
Start the engine and check that the pre-filter does not
leak.