Transport, Set-up and Connection
4 — 4
04_0009_0508GB
The following section describes how to connect the high-pressure
cleaner to the water supply.
1
2
Item
Designation
1
Connecting to the mains water supply
2
Connection for the high-pressure hose
The water supply may only be connected as per DIN 1988 -- Techni-
cal Rules for Water Installations, i.e. by means of installation type 1
backflow preventers or an independent outlet (buffer tank with a boo-
ster pump).
Please ensure that you check preconditions for connection to the wa-
ter supply before beginning connection work.
-- The pipe must be at least 3/4” in diameter.
-- The available water pressure must be at least 2 bar.
Water pipes must be laid visibly, taking local conditions into conside-
ration, and protected against damage. They must not be allowed to
obstruct operating personnel.
Continuation next side
4.5
Water connections