Faults, Cause and Remedy
7 — 4
06_0007_0508GB
The fuse has triggered
Cause
Remedy
The fuse on the machine is too
small.
Use the correct fuse.
The fuse triggers too readily.
Use the correct fuse.
The diameter of the electric
supply lead is too narrow.
Use a supply lead with a larger diameter.
The motor protection switch has triggered
Cause
Remedy
The diameter of the electric
supply lead is too narrow.
Use a supply lead with a larger diameter.
The electric supply lead is
wound up, e.g. on a cable
drum.
Unwind the supply lead.
The electrical connection is not
compatible with the mains
frequency.
Compare the mains frequency with the machine frequency
specified on the rating plate. The two frequencies must
correspond.
Ventilation for the drive motor
is insufficient.
Position the machine so that sufficient air circulates around the
drive motor.