Sensor signals
• Voltage signal
0-10 VDC, R
i
> 0 k
Ω
(via internal voltage supply).
Tolerance: + 0 %/- 3 % at maximum voltage signal.
Screened cable: 0.5 - 1.5 mm
2
/ 28-16 AWG.
Maximum cable length: 500 m.
• Current signal
DC 0-20 mA/4-20 mA, R
i
= 175
Ω
.
Tolerance: + 0 %/- 3 % at maximum current signal.
Screened cable: 0.5 - 1.5 mm
2
/ 28-16 AWG.
Maximum cable length: 500 m.
• Electricity supply to sensor:
+24 VDC, max. 40 mA.
+10 VDC, max. 2.5 mA.
Signal output
Potential-free changeover contact.
Maximum contact load: 250 VAC, 2 A.
Minimum contact load: 5 VDC, 10 mA.
Screened cable: 0.5 - 2.5 mm
2
/ 28-12 AWG.
Maximum cable length: 500 m.
Bus input
Grundfos bus protocol, GENIbus protocol, RS-485.
Screened 3-core cable: 0.5 - 1.5 mm
2
/ 28-16 AWG.
Maximum cable length: 500 m.
19. Other technical data
EMC (electromagnetic compatibility)
EN 61800-3.
Residential areas
-
unlimited distribution, corresponding to
CISPR 11, class B, group 1.
Industrial areas - unlimited distribution, corresponding to
CISPR 11, class A, group 1.
Contact Grundfos for further information.
Enclosure classe
Standard: IP55 (IEC 34-5).
Insulation class
F (IEC 85).
Ambient temperature
• During operation: -20 °C to +40 °C.
• During storage/transport: -40 °C to +60 °C.
Relative air humidity
Maximum 95 %.
19.1 Sound pressure level
Single-phase motors:
< 70 dB(A).
Three-phase motors:
20. Disposal
This product or parts of it must be disposed of in an
environmentally sound way:
1. Use the public or private waste collection service.
2. If this is not possible, contact the nearest Grundfos company
or service workshop.
Subject to alterations.
Motor
[kW]
Speed stated
on nameplate
[min
-1
]
Sound pressure
level
[dB(A)]
0.75
1400-1500
52
2800-3000
63
1.1
1400-1500
52
2800-3000
63
1.5
1400-1500
53
2800-3000
63
2.2
1400-1500
52
2800-3000
64
3.0
1400-1500
57
2800-3000
64
4.0
1400-1500
59
2800-3000
68
5.5
1400-1500
59
2800-3000
68
7.5
2800-3000
68
Summary of Contents for VT Booster Set
Page 1: ...VT Booster Set O M Manual...
Page 3: ...1 Important Health Safety Information Page 3 VT Booster Set...
Page 10: ...2 System Information Installation and Commissioning Page 10 VT Booster Set...
Page 11: ...2 1 Booster Set Components VT Booster Set Components Page 11 VT Booster Set...
Page 12: ...2 2 Control Panel Wiring Diagrams Twin Pump Wiring Diagram Single Phase Page 12 VT Booster Set...
Page 13: ...Twin Pump Wiring Diagram 3 Phase Page 13 VT Booster Set...
Page 15: ...VR VASCO Cold Water Booster Sets Page 15 VT Booster Set...
Page 16: ...VT3 Three Phase Control Panel Wiring Diagram Page 16 VT Booster Set...
Page 17: ...Page 16a VT Booster Set...
Page 23: ...3 User Maintenance and Troubleshooting Page 22 VT Booster Set...
Page 43: ...Appendix 14...
Page 50: ...Appendix 21...
Page 51: ...Appendix 22...
Page 55: ...Appendix 26...
Page 56: ...Appendix 27...