English (GB)
41
16. Factory settings
1)
Only available if you have fitted an advanced functional module (FM300).
17. Disposal
This product or parts of it must be disposed of in an
environmentally sound way:
1. Use the public or private waste collection service.
2. If this is not possible, contact the nearest Grundfos company
or service workshop.
The waste battery should be disposed of through the national
collective schemes. If in doubt, contact your local Grundfos
company.
Subject to alterations.
●
Function is enabled.
❍
Function is disabled.
-
Function is not available.
Settings
CRE, CRIE, CRNE, SPKE, MTRE
Function
description
With factory mounted
sensor
Without factory
mounted sensor
CME
Setpoint
67 % of sensor range
67 % of sensor range
67 % of sensor range
Page
Operating mode
Normal
Normal
Normal
Page
Control mode
Constant pressure
Constant pressure
Constant pressure
Page
Pipe filling function
Not active
Not active
Not active
Page
Buttons on product
Active
Active
Active
Page
Stop function (Low-flow stop function)
Not active
Not active
Not active
Page
Controller (Controller settings)
●
●
●
Page
Ti
0.5
0.5
0.5
Kp
0.5
0.5
0.5
Operating range
13-100 %
13-100 %
13-100 %
Page
Ramps
Page
Ramp-up
1 second
1 second
1 second
Ramp-down
3 second
3 second
3 second
Number (Pump number)
-
-
-
Page
Radio communication
Active
Active
Active
Page
Analog input 1
4-20 mA
Not active
Not active
Page
Analog input 2
Not active
Not active
Not active
Analog input 3
Not active
Not active
Not active
Pt100/1000 input 1
Not active
Not active
Not active
Page
Pt100/1000 input 2
Not active
Not active
Not active
Digital input 1
External stop
External stop
External stop
Page
Digital input 2
Not active
Not active
Not active
Digital in/output 3
Not active
Not active
Not active
Page
Digital in/output 4
Not active
Not active
Not active
Pulse flowmeter
❍
❍
❍
Page
Predefined setpoints
0 bar
0 %
0 %
Page
Analog output
Not active
Not active
Not active
Page
External setpoint function
Not active
Not active
Not active
Page
Signal relay 1
Not active
Not active
Not active
Page
Signal relay 2
Not active
Not active
Not active
Limit 1 exceeded
Not active
Not active
Not active
Page
Limit 2 exceeded
Not active
Not active
Not active
Standstill heating
Not active
Not active
Not active
Page
Motor bearing monitoring
Active
Active
Active
Page
Pump name
-
-
-
Page
Connection code
-
-
-
Page
Unit configuration
SI
SI
SI
Page
Summary of Contents for VT Booster Set
Page 1: ...VT Booster Set O M Manual...
Page 3: ...1 Important Health Safety Information Page 3 VT Booster Set...
Page 10: ...2 System Information Installation and Commissioning Page 10 VT Booster Set...
Page 11: ...2 1 Booster Set Components VT Booster Set Components Page 11 VT Booster Set...
Page 12: ...2 2 Control Panel Wiring Diagrams Twin Pump Wiring Diagram Single Phase Page 12 VT Booster Set...
Page 13: ...Twin Pump Wiring Diagram 3 Phase Page 13 VT Booster Set...
Page 15: ...VR VASCO Cold Water Booster Sets Page 15 VT Booster Set...
Page 16: ...VT3 Three Phase Control Panel Wiring Diagram Page 16 VT Booster Set...
Page 17: ...Page 16a VT Booster Set...
Page 23: ...3 User Maintenance and Troubleshooting Page 22 VT Booster Set...
Page 43: ...Appendix 14...
Page 50: ...Appendix 21...
Page 51: ...Appendix 22...
Page 55: ...Appendix 26...
Page 56: ...Appendix 27...