Duplomatic MS
S.p.A
. ▪ ED
M-M*/30 Start-
up Manual ▪
89251/218
ETM ▪
Jun 2018
page 5 of 29
Available versions
EDM-M
z xx hh
/30 E
y
-
k
The functionalities of the module can be chosen by the proper ordering code, where:
-
Z
is the type of valve / valves to be driven.
1 - single valve with one solenoid
2 - single valve with two solenoids
3 - two valves with one solenoid each, (separate channels, EDM-M3 can manage even
two different type of valves)
-
X
indicates the nominal current required.
Two digits - XX - appear in M3 version only, because of the separate channels which
require entries for each coil.
Please note that option 5 is not settable for the 2
nd
channel, so if you have a coil with
this requirement link it with the 1
st
channel.
1
–
860 mA
2
–
1200 mA
3
–
1600 mA
4
–
1880 mA
5
–
2600 mA
-
H
indicates the choices for PWM frequency
Two digits - HH - appear in M3 version only, because of the different PWM value that
each solenoid requires.
1
–
100 Hz
2
–
200 Hz
3
–
300 Hz
4
–
400 Hz
-
Y
indicates the type of reference signal
0 = reference signal in voltage
0…10V or ±10 V depending on
Z
choice,
1 = reference signal in current
4…20 mA
-
K
indicates PIN12 setting as digital INPUT or digital OUTPUT
A = Pin 12 used for external enable (Non-existing configuration in previous series 20)
B = Pin 12 used for V aux (internal enable) - Series 20 compatible.