Duplomatic MS
S.p.A
. ▪ ED
M-M*/30 Start-
up Manual ▪
89251/218
ETM ▪
Jun 2018
page 27 of 29
Function
Series 20
parameter
Series 30 parameter
EDM
TYPE
Series 20
values
Series 30 values
Outp
u
t
P
ara
m
ete
rs
Cu
rren
t
Coil Type
(PO1)
CURRENT
M1 or
M2
200 - CURRENT_LIM
[mA]
Coil Type
(PO1, PO2)
CURRENT1, CURRENT2
M3
Ad
ju
stm
ent
VT
(PI1)
ADJ_TRIGGER
M1 or
M2
0-200
[1/100V]
0-20%
of
scaled reference
VT
(PI1, PI2)
ADJ1_TRIGGER,
ADJ2_TRIGGER
M3
I Min (PO1)
ADJ_MIN
M1
mA
mA
or
CURRENT%
I Min
(PO1, PO2)
ADJ_MIN_A, ADJ_MIN_B
M2
I Min
(PO1, PO2)
ADJ1_MIN, ADJ2_MIN
M3
I Max (PO1)
ADJ_MAX
M1
mA
mA
or
CURRENT%
I Max
(PO1, PO2)
ADJ_MAX_A,
ADJ_MAX_B
M2
I Max
(PO1, PO2)
ADJ1_MAX, ADJ2_MAX
M3
P
W
M
freq
u
ency
PWM Freq
PWM
M1 or
M2
50…500 [
Hz]
70…500 [Hz]
PWM1, PWM2
M3
D
ith
er
Dither
[mA]
DITHER_AMP [%]
M1 or
M2
0…99 [mA]
mA or
0…15 %
of CURRENTx
DITHER1_AMP [%],
DITHER2_AMP [%]
M3
Dither Freq
[Hz]
DITHER_FREQ [%]
M1 or
M2
10
…
PWM/2
if
PWM
≤ 1
98
0
…
PWM/2
DITHER1_FREQ,
DITHER2_FREQ [%]
M3
10
…
99 if
PWM > 198