Duplomatic MS
S.p.A
. ▪ ED
M-M*/30 Start-
up Manual ▪
89251/218
ETM ▪
Jun 2018
page 19 of 29
ADJx_MIN
ADJx_MAX
ADJx_TRIGGER
x = 1|2
0
–
50%
ADJ_MIN
–
120%
0
–
20%
USR
M3 version
PWM
According with ordered
code
70
–
500 Hz
USR
M1-M2
versions
PWM1
PWM2
According with ordered
code
70
–
500 Hz
USR
M3 version
DITHER_AMP
DITHER_FREQ
0%
0Hz
0
–
15%
0
–
PWM/2 Hz
USR
M1-M2
versions
DITHERx_AMP
DITHERx_FREQ
x = 1|2
0%
0Hz
0
–
15%
0
–
PWMx/2 Hz
USR
M3 version
ADJ_MIN, ADJ_MAX
and
DITHER_AMP, DITHER_FREQ
parameters can be displayed in both
absolute (mA) and percentage unit. This option can be set by the proper check box in the
configuration software.
ADJ_TRIGGER
can be displayed in absolute unit only (mA).
Configuration
DIAGNOSTICS (failure monitoring)
Command
Parameters
Unit
User Level/Group
Default
DIAGNOSTICS X
x = ENABLE|DISABLE|AUTO
-
USR
ENABLE (A version)
AUTO (B version)
Activation of the monitoring functions of the module.
The monitoring functions should be always active because otherwise no errors are detectable
via the READY output. Deactivation is possible mainly for troubleshooting.
ENABLE
: All monitoring functions are active. Detected failures can be reset by deactivating the
ENABLE input for A version or switching off/on the card for the B version.
AUTO
: Auto reset mode. All monitoring functions are active. If the failure does not exist
anymore, the module automatically resumes to work.
DISABLE
: No monitoring function is active.