background image

 

 page 18 of 29 

 

 Duplomatic MS

 

S.p.A

. ▪

  EDM-M*/30  Start-

up Manual  ▪  

89251/218 

ETM   ▪  

Jun 2018

 

SIGNAL_OFFSET 
 

0.00 

-

3.000…+3.000 V

 

-

4.000…+4.000mA

 

Unit according with signal 
type 

USR 

M1-M2 
versions 

SIGNAL1_OFFSET 
SIGNAL2_OFFSET 

0.00 

-

3.000…+3.00

0 V 

-

4.000…+4.000

 mA  

Unit according with signal 
type 

USR 

M3 version 

SIGNAL_GAIN 
 

1.000 

0.400…10.000

 

USR 

M1-M2 
versions 

SIGNAL1_GAIN 
SIGNAL2_GAIN 

1.000 

0.400…10.000

 

USR 

M3 version 

RAMP_UP 
RAMP_DOWN 


 20000 ms 

USR 

M1 version 

RAMP_UP_A 
RAMP_DOWN_A 
RAMP_UP_B 
RAMP_DOWN_B 




 20000 ms 

USR 

M2 version 

RAMPx_UP 
RAMPx_DOWN 
x= 1|2 


 20000 ms 

USR 

M3 version 

CURRENT 

According with ordered 
code 

200 

 CURRENT_LIM mA 

USR 

M1-M2 
version 

CURRENT1 
CURRENT2 

According with ordered 
code 

200 

 CURRENT1_LIM 

200 

 CURRENT2_LIM 

mA 

USR 

M3 versions 

CURRENT_LIM 

According with ordered 
code 

860…3400 mA

 

RO 

M1-M2 
version 

CURRENT1_LIM 
CURRENT2_LIM 

According with ordered 
code 

860…3400

 mA 

860…2600

 mA 

RO 

M3 version 

ADJ_MIN 
ADJ_MAX 
ADJ_TRIGGER 

According with version 
100% 
1.5% 

 50% 

ADJ_MIN 

 120% 

 20% 

USR 

M1 version 

ADJ_MIN_A 
ADJ_MAX_A 
ADJ_TRIGGER 
ADJ_MIN_B 
ADJ_MAX_B 

According with version 
100% 
1.5% 
According with version 
100% 

 50% 

ADJ_MIN_A 

 120%  

 20% 

ADJ_MIN_B 

 120% 

 50% 

USR 

M2 version 

Summary of Contents for EDM-M*/30 Series

Page 1: ...89251 218 ETM EDM M 30 Digital Card Start up manual Duplomatic MS Spa...

Page 2: ...M3 13 Wiring 14 Card Setup 15 EDMPC 30 kit 15 EBC App 15 EBC configurator software 16 Parameters 17 Summary 17 Configuration 19 DIAGNOSTICS failure monitoring 19 ENABLE to activate external enable of...

Page 3: ...erature about EDM M 30 and its start up can be found in Technical catalogue 89251 218 ED Software pack EBC Software v 3 1 0 0 and later For installation start up commissioning and maintenance use only...

Page 4: ...olenoid according to the reference signal and independently of temperature variations or load impedance The card uses micro USB interface and via software EBC configurator it is possible to set parame...

Page 5: ...quire entries for each coil Please note that option 5 is not settable for the 2nd channel so if you have a coil with this requirement link it with the 1st channel 1 860 mA 2 1200 mA 3 1600 mA 4 1880 m...

Page 6: ...ut value can be compensated using the deadband compensation parameter set The maximum current that can be provided to a coil is 120 of the CURRENT parameter The upper limit of CURRENT is set by CURREN...

Page 7: ...ion consistent Blinking Failure as described in the table below L5 L6 not used LED Card model Function Slow Flashing Fast Flashing L1 M1 Reference Signal missing M2 M3 Reference 1 L2 M1 Solenoid Coil...

Page 8: ...output current V V mA Logic 0 2 Logic 1 max Ub 50 Analogue input mA V V 4 20 Ri 56 ohm 10 differential signal Ri 11 kohm 0 10 Ri 11 kohm PWM Output current mA 200 4000 step less PWM frequency Hz 100 5...

Page 9: ...Duplomatic MS S p A EDM M 30 Start up Manual 89251 218 ETM Jun 2018 page 9 of 29 Overall and mounting dimensions...

Page 10: ...must be laid separately from power cables Analogue signal cables must be screened All other cables must be screened if there are powerful interference sources frequency converters power contactors an...

Page 11: ...Supply PIN 1 Power supply PIN 2 0 V GND Power supply ground 0 V reference for PIN 9 0 V reference for PIN 12 in EDM M version B Connection PWM output PIN 3 4 Current controlled PWM output for the sol...

Page 12: ...0 10 V or 4 12 20 mA PIN 8 0 V reference for the input signal Connection IO PIN 9 Digital output for card status LOW power output not enabled HIGH card ok power out enabled PIN 12 VERSION A Digital in...

Page 13: ...n channel 1 PIN 10 Channel 2 Reference signal 2 corresponds with 0 10 V or 4 20 mA PIN 11 0 V reference for the reference signal in channel 2 Connection IO PIN 9 Digital output for card status LOW pow...

Page 14: ...page 14 of 29 Duplomatic MS S p A EDM M 30 Start up Manual 89251 218 ETM Jun 2018 Wiring...

Page 15: ...d Ordering code 3898201020 EBC App This app has been developed in order to offer immediate diagnostic and configuration activities of USER level parameters of electronic cards even in the field with a...

Page 16: ...System Requirements Settings The EBC software can be installed on every machine equipped with Microsoft OS Windows 7 8 and 10 a free USB port to connect the communication cable standard cable type US...

Page 17: ...parameters will be marked as RO Read Only Summary Parameter Default value Range User level Group OEM_INFO Manufacturing date RO BOARD CONFIGURATION According with ordered code M1 M2 M3 RO DIAGNOSTICS...

Page 18: ..._B 0 0 0 0 0 20000 ms USR M2 version RAMPx_UP RAMPx_DOWN x 1 2 0 0 0 20000 ms USR M3 version CURRENT According with ordered code 200 CURRENT_LIM mA USR M1 M2 version CURRENT1 CURRENT2 According with o...

Page 19: ...software ADJ_TRIGGER can be displayed in absolute unit only mA Configuration DIAGNOSTICS failure monitoring Command Parameters Unit User Level Group Default DIAGNOSTICS X x ENABLE DISABLE AUTO USR ENA...

Page 20: ...and Parameters Unit User Level Group Default SIGNAL_OFFSET 3 000 3 000 4 000 4 000 V mA USR M1 M2 0 00 SIGNAL1_OFFSET SIGNAL2_OFFSET 3 000 3 000 4 000 4 000 V mA USR M3 1 000 SIGNAL_GAIN Command Param...

Page 21: ...User Level Group Default RAMP_UP RAMP_DOWN 0 20000 ms USR M1 0 RAMP_UP_A RAMP_DOWN_A RAMP_UP_B RAMP_DOWN_B 0 20000 ms USR M2 0 RAMP1_UP RAMP1_DOWN RAMP2_UP RAMP2_DOWN 0 20000 ms USR M3 0 Entered ramp...

Page 22: ...e then adjusted by parameters for Curve adjustment CURRENT and RESIST values are internally used by the card for an optimum current control loop For a correct behavior EDM M model must be ordered with...

Page 23: ...ADJ1_TRIGGER ADJ2_MIN ADJ2_MAX ADJ2_TRIGGER 0 50 ADJ1_MIN 120 0 20 0 50 ADJ2_MIN 120 0 20 USR M3 0 100 1 5 0 100 1 5 With these commands the output signal is adjusted to the valve characteristics The...

Page 24: ...depends on the valve type DITHER_AMP DITHER_FREQ Command Parameters Unit User Level Group Default DITHER_AMP DITHER_FREQ 0 15 0 PWM 2 Hz USR M1 M2 0 DITHER1_AMP DITHER1_FREQ DITHER2_AMP DITHER2_FREQ...

Page 25: ...ent of solenoid Output current of solenoid A CH1 M2 Output current of solenoid B CH2 M2 Output current of solenoid CH1 M3 Output current of solenoid CH2 M3 mA CURRENT_ERR CURRENT_ERR_A CURRENT_ERR_B C...

Page 26: ...ameter Series 30 parameter EDM TYPE Series 20 values Series 30 values Configuration Controlled valve EDM_TYPE 1 Valve Mono M1 1 Valve Double M2 2 Valves Mono M3 Prod field Week EDM_IDS Free string Fre...

Page 27: ...caled reference VT PI1 PI2 ADJ1_TRIGGER ADJ2_TRIGGER M3 I Min PO1 ADJ_MIN M1 mA mA or CURRENT I Min PO1 PO2 ADJ_MIN_A ADJ_MIN_B M2 I Min PO1 PO2 ADJ1_MIN ADJ2_MIN M3 I Max PO1 ADJ_MAX M1 mA mA or CURR...

Page 28: ...page 28 of 29 Duplomatic MS S p A EDM M 30 Start up Manual 89251 218 ETM Jun 2018 APPENDIX 2 Block diagrams EDM M1 EDM M2...

Page 29: ...Duplomatic MS S p A EDM M 30 Start up Manual 89251 218 ETM Jun 2018 page 29 of 29 EDM M3 Function of pin 12...

Reviews: