page 20 of 29
Duplomatic MS
S.p.A
. ▪
EDM-M*/30 Start-
up Manual ▪
89251/218
ETM ▪
Jun 2018
ENABLE (to activate external enable of power stage)
Command
Parameters
Unit
User Level/Group
Default
ENABLE
INT | EXT
-
USR / A version
EXT
This function enables or disables the use of external enable on pin 12.
With ENABLE = INT, the card enables the output power stage automatically after the power-on
(with a delay time of approx. 0.5s).
This parameter is available only for A version of EDM-M card.
Analog input
SIGNAL_OFFSET
Command
Parameters
Unit
User Level/Group
Default
SIGNAL_OFFSET
-3.000/+3.000
-4.000/4.000
V
mA
USR / M1-M2
0.00
SIGNAL1_OFFSET
SIGNAL2_OFFSET
-3.000/+3.000
-4.000/4.000
V
mA
USR / M3
1.000
SIGNAL_GAIN
Command
Parameters
Unit
User Level/Group
Default
SIGNAL_GAIN
0.400-10.00
-
USR / M1-M2
0.00
SIGNAL1_GAIN
SIGNAL2_GAIN
0.400-10.00
-
USR / M3
1.000
Signal scaling example:
With an EDM-M2**/30E0-* the available signal type is -10
…
0
…
+10V.
If application signal is 0…2.5…5V this means:
▪
0% signal for the valve must be moved from 2.5V (application 0%) to 0V - >
SIGNAL_OFFSET = Standard Offset
–
Application Offset = 0 - 2.5 = - 2.5 V
▪
Signal input must be scaled from 2.5V to Standard Full Scale of 10V - >
SIGNAL_GAIN = Standard F.S. / Application F.S. = 10 / 2.5 = 4.0