Duplomatic MS
S.p.A
. ▪ ED
M-M*/30 Start-
up Manual ▪
89251/218
ETM ▪
Jun 2018
page 17 of 29
Parameters
At software launch, the parameters are displayed in read only mode.
Parameter configuration is structured with different access levels.
To access
“User”
parameter config in the EBC software you need to log in with the following
case-sensitive credentials:
Login:
USR
Pwd:
Dol732
Figure 1 -Password ICON
All displayed but
not changeable
parameters will be marked as
RO (Read Only)
Summary
Parameter
Default value
Range
User
level
Group
OEM_INFO
Manufacturing date
RO
BOARD
CONFIGURATION
According with ordered
code
M1 | M2 | M3
RO
DIAGNOSTICS
AUTO (for B version)
ENABLE (for A version)
ENABLE|DISABLE|AUTO
USR
ENABLE
EXT
INT|EXT
USR
version A
only
RESIST
According with ordered
code
0
–
30 Ohm
RO
M1-M2
version
RESIST1
RESIST2
According with ordered
code
0
–
30 Ohm
RO
M3 versions
SIGNAL_TYPE
According with ordered
code
0…10V | 4…20mA
(M1 version)
+/-
10V | 4…12…20mA
(M2 version)
RO
M1-M2
versions
SIGNAL1_TYPE
SIGNAL2_TYPE
According with ordered
code
0…10V | 4…20mA
RO
M3 version