60 Hz HRSC ELECTRICAL DATA (50 - 150)
VOLTAGE TOLERANCES:
1) 208 volt: min. 187, max. 229
2) 230 volt: min. 207, max. 253
3) 460 volt: min. 414, max. 506
208/230
XL
205
205
205
-
1228
1228
1228
-
667
-
800
-
208/230
XL
205
205
205
-
409
409
409
-
667
-
800
-
460
Y-D
91
91
91
-
485
485
485
-
296
-
350
-
460
XL
91
91
91
-
162
162
162
-
296
-
350
-
208/230
Y-D
209
209
209
-
1415
1415
1415
-
471
262
600 450
208/230
XL
209
209
209
-
472
472
472
-
471
262
600 450
460
Y-D
98
98
98
-
539
539
539
-
312
-
400
-
460
XL
98
98
98
-
180
180
180
-
312
-
400
-
208/230
Y-D
209
209
209
-
1415
1415
1415
-
471
262
600 450
208/230
XL
209
209
209
179
472
472
472
-
471
262
600 450
460
XL
98
98
98
74
539
539
539
-
319
-
400
-
460
Y-D
98
98
98
74
180
180
180
-
319
-
400
-
208/230
XL
205
205
205
205 1228
1228
1228
1228
462
462
600 600
208/230
Y-D
205
205
205
205
409
409
409
409
462
462
600 600
460
XL
91
91
91
91
485
485
485
485
387
-
450
-
460
Y-D
91
91
91
91
162
162
162
162
387
-
450
-
208/230
XL
209
209
209
209 1415
1415
1415
1415
467
462
600 600
208/230
Y-D
209
209
209
209
472
472
472
472
467
462
600 600
460
XL
98
98
98
98
539
539
539
539
396
-
450
-
460
XL
98
98
98
98
180
180
180
180
396
-
450
-
208/230
Y-D
209
209
209
209 1415
1415
1415
1415
471
462
600 600
208/230
XL
209
209
209
209
472
472
472
472
471
462
600 600
460
Y-D
98
98
98
98
539
539
539
539
403
-
500
-
460
XL
98
98
98
98
180
180
180
180
403
-
500
-
208/230
Y-D
209
209
209
209 1415
1415
1415
1415
471
471
600 600
208/230
XL
209
209
209
209
472
472
472
472
471
471
600 600
460
Y-D
98
98
98
98
539
539
539
539
417
-
500
-
460
XL
98
98
98
98
180
180
180
180
417
-
500
-
Model
HRSC
Volts
60 Hz.
3 PH.
Type
of
Unit
1 2 3 4 1 2 3 4 Cir. 1 Cir. 2 Cir. 1 Cir. 2
NOTES:
1. XL: Across the line; Y-D: Star-Delta
2. RLA (Rated Load Amps) rated in accordance with ARI Standard 590.
3. Starting current for normal Y-D start is shown. In certain compressor failure modes, Y-D inrush can be as high as XL
inrush.
4. Wire Size Amps (ampacity) equal 125% of the rated load amps for the largest motor in the circuit plus 100% of the
rated load amps for all other motors in the circuit, per N.E.C.
5. Maximum fuse size is based on 225% of the rated load amps for the largest motor in the circuit plus 100% of the rated
load amps for all other motors in the circuit. This is the largest fuse allowed per N.E.C. A smaller fuse is often recom-
mended based on unit application and ambient temperature.
RATED LOAD AMPS
MOTOR NO.
LOCKED ROTOR AMPS
MOTOR NO.
Minimum
Circuit
Ampacity
Maximum
Fuse
Size
COMPRESSORS
180
210
225
240
255
270
300
18