![Ducati SBK848 EVO 2011 Owner'S Manual Download Page 33](http://html1.mh-extra.com/html/ducati/sbk848-evo-2011/sbk848-evo-2011_owners-manual_2537731033.webp)
32
E
Instrument panel diagnostics
Important
The instrument runs the system diagnostics correctly
60 seconds after the last Key-Off.
Any errors detected in the behaviour of the motorcycle are
displayed.
If there are several errors, they are displayed in rolling mode
every 3 seconds.
The table below shows the errors that can be displayed.
Warning
When an error is displayed, always contact a Ducati
Dealer or authorised Service Center.
ERROR MESSAGE
ERROR
COIL
8.1
Horizontal cylinder coil error
COIL
8.2
Horizontal cylinder coil error
COIL
9.1
Vertical cylinder coil error
COIL
9.2
Vertical cylinder coil error
COIL
10.1
Horizontal cylinder coil error
COIL
10.2
Horizontal cylinder coil error
COIL
11.1
Vertical cylinder coil error