screws for fixing the rack, bolts and nuts or bolts for fixing to the ground of the engine. Silicone to seal the holes 
to run cables to the motor.

1. KIT ConTEnTS, ACCESSoRIES AnD TECHnICAL DATA

See table 1 & 2
Warning: the composition of the kit may vary depending on the version purchased.
There are special versions with ad hoc compositions. The table of this manual is for guidance only and does not 
represent the totality of the available versions.

2. oPERATIng LIMITS 

Ensure that the dimensions of the engine are compatible with the structure. Fig.3
Make sure that the weight limits and length of the engine are compatible with the gate. TABLE 2

ATTEnTIon: 

The drive is suitable for sliding gates installed in a workmanlike manner with excellent balance and 

linear motion without friction.
If the gate is not up to standard, it cannot be automated.
If manual handling is not linear and smooth without major points of friction the gate can’t be automated
The automation system cannot compensate for defects in the structure. Make sure the gate is in compliance with 
the general or local safety standards.

DAngER WARnIng: 

The gate must have some mechanical limit stop 

(end-of-travel-limits)

 with setback. 

Otherwise the gate is dangerous and could derail from the track causing a serious risk danger to persons or 
property.

DAngER WARnIng:

 in the absence of mechanical stops do not automate and not even manually move the 

gate but please report immediately to a specialist for the put to norm of the structure.
The manufacturer is not liable for damage caused by incorrect installation of structures unfit or unsafe.

3. PRELIMInARY PREPARATIonS

To power the engine a specialist operator shall prepare (except for solar-powered kit) the Supply Electric cable 
230V 50Hz (or 110V 60H) with output at the point where the engine will be fixed to the ground.
To check the fixing position of the motor to the ground see Figure 2-4-7C-10-11
Provide ducts for cables and related accessories cable mm 0.25 mm²

DAngER WARnIng:

 The connection of the high voltage 230V 50Hz (or 110V 60Hz) must only be carried out 

by suitably qualified and certified electrician.
The other low voltage electrical connections can also be made by any operator, as low voltage, present no 
danger of electric shock.

4. MoToR FIXIng PoSITIon: RIgHT oR LEFT SIDE oF THE gATE

The motor must be positioned on the ground, parallel to the gate, a small pedestal in concrete or brick. 
An  optional “mounting plate” is also avalable fo reasier motor position adjustment. Optional accessory PLAK 
8700 (GASL001). Fig. 5A-5B

The engine must be installed inside the property at the level of the column corresponding to the opening side of 
the door. FIG 2 and 4A-4B
It is important to calculate the fixing position of the motor in accordance with the measures and limits set by the 
FIG.7C

The optional accessory PLAK8700 is recommended because it allows you to adjust the longitudinal and lateral 
position of the motor to the rack that will be fitted to the gate.
The engine shall be placed parallel to the gate and perfectly horizontally. Figure 2

5. EngInE CABLE ConnECTIon: gate that opens to the right or to the left

Automation is wired for STANDARD opening. We consider standard a gate that opens to to the right (seen from 
the inside of the Property):
if the gate open to the left is necessary to reverse the polarity of the motor cables red and blue being careful not 
to damage the blades brush holders. Fig.4a-4B

6. gRoUnF MoToR FIXIng

After determining the correct fixing position and height of the engine and having prepared the conduits for the 
passage of cables, place the motor in the final fixing position (if the engine is fastened to the ground without 
adjustment plate, a base should be perfectly linear plan. Attach the motor to the base by means of special bolts 
(not supplied). In case of using the optional fixing plate cemented it to the ground. FIG. 5A-B-C

Summary of Contents for Manual Slide

Page 1: ...RICANCELLI SCORREVOLI OUVRE PORTAIL COULISSANT SLIDING GATE OPENER AUTOMATIZACIONES PARA PUERSTAS CORREDERAS SCHIEBETORANTRIEB H O M E H O M E DU CATI a u t o m a t i o n a u t o m a t i o n MANUALE S...

Page 2: ...l optional optional SW7120 optional optional optional optional optional optional Fash 7012 optional optional optional optional 1 1 Fash 7120 optional optional optional optional optional optional optio...

Page 3: ...600kg 8m CTH43 no SL 843 230V 12V 200 800kg 12m CTH43 no SL 640 230V BATT SOL 12V 140 600kg 8m CTH46 yes SL 840 230V BATT SOL 12V 200 800kg 12m CTH46 yes Table 01 ON OFF DUCATI HOME SOLAR OPION 230 V...

Page 4: ...4 FIG 04 A FIG 04 B FIG 05 A FIG 05 B LOCK UNLOCK FIG 06 FIG 05 C OPTIONAL PLAK 8700 RED BLUE BLUE RED...

Page 5: ...5 FIG 09 FIG 7 C FIG 7 D 105mm 0 1 33 mm 0 2 Portail FIG 7 A 1 2 mm max FIG 11 R M FIG 10 R M FIG 12 R M R M A B FIG 7 B FIG 08...

Page 6: ...6 230 V FUSE T0 8A FIG 13 FIG 14 A FIG 14 B FIG 15 A FIG 15 B CTH 43 CTH 43 CTH 46 CTH 46 N L...

Page 7: ...7 START TRANSFORMER 0 BLACK 12 V YELLOW FUSE T 0 8A C NO 24V 0 sec 100 sec C M BAT optional battery changer Battery PHOTOCELLS SW 7012 12 V 10W MAX 230V 0 100 RX TX FIG 16 CTH 43 N L...

Page 8: ...8 PED START TRANSFORMER 0 BLACK 12 V YELLOW FUSE T0 8A PHOTOCELLS SW 7120 12 V 10W MAX 0 100 RX TX FUSE T0 8A FIG 17 A CTH 46...

Page 9: ...9 TERMINAL PHOTOCELLS SW7012 CTH 46 FCT RX TX FIG 17 B FIG 18 FIG 22 FIG 21 FIG 20 FIG 19 FIG 23 FIG 24...

Page 10: ...ll local electrical and building codes During installation Ensure your personal safety Never wear watches rings or loose clothing while installing or servicing the opening system They could get caught...

Page 11: ...hether moving open closed or stopped Never permit children to play with the door opener s remote control buttons or transmitters and do not allow children to use them to operate the door opener Always...

Page 12: ...k the fixing position of the motor to the ground see Figure 2 4 7C 10 11 Provide ducts for cables and related accessories cable mm 0 25 mm DANGER WARNING The connection of the high voltage 230V 50Hz o...

Page 13: ...THE RACK Proceed as in fig 9 inserting the two media magnet along the rack through the interlocking system Slide the two supports up to min 10 cm from the ends of the gate See fig 12 for the moment th...

Page 14: ...f the final position of the end stops proceed in two stages Before final fixing place the magnets momentarily to 10 cm before the desired final stop position of the gate in order to make sure that the...

Page 15: ...mer Power must be fully rotated CLOCKWISE setting power to the maximum FIG 16 17 A ATTENTION ALL ADJUSTMENTS SHOULD BE MADE TO THE GATE CLOSED The regulations will be effective only in the next cycle...

Page 16: ...r versions with electonic board CTH46 15 3 Key switch SW5000 KEY5000 The key switch is a wired device that allows you to operate your door The contact is NO Turnthe key to activate the command Connect...

Page 17: ...code the keyboard is synchronized to the electronic automation in the same way in which you store the codes of other remote controls see paragraph 12 Warning Write down your personal code and keep it...

Page 18: ...keyboard is in the process of flashing The keypad beeps to confirm the operation CAUTION After this operation the keyboard will resume the standard code 1111 but you can not use it to control the gat...

Page 19: ...ttere in buono stato il cancello e la struttura prima di procedere all installazione dell automatismo onde evitare qualsiasi rischio di danni ferite gravi o morte Prima dell installazione riparate o s...

Page 20: ...oni o decesso Fissare in prossimit della porta automatizzata un pannello visibile e permanente di avviso e segnalazione della presenza di un sistema automatizzato Senza un sistema di sicurezza special...

Page 21: ...ATTENZIONE PERICOLO Il cancello deve avere dei fine corsa meccanici di fermo con battuta di arresto in caso contrario il cancello pericoloso e potrebbe deragliare dal binario causando un grave rischi...

Page 22: ...er accedere all interno della propriet 8 FISSAGGIO DELLA CREMAGLIERA La cremagliera mod 8602 fornita in spezzoni da 50cm con un sistema ad incastro a coda di rondine FIG 7 B Ogni spezzone va singolarm...

Page 23: ...di collegamento alla batteria sono gi forniti con la scheda Attenzione rispettare le polarit dei cavi di collegamento alla batteria Attenzione la batteria va collegata a massimo livello di carica Prim...

Page 24: ...gni tasto del radiocomando corrisponde ad 1 canale Se si necessita pi capacit di memoria disponibile una ricevente esterna optional a 4 canali modello RIXY 6040 6040 Rol con una capacit di 40 codici o...

Page 25: ...cezione in fase di chiusura gi in corso ATTENZIONE ATTENZIONE TUTTE LE REGOLAZIONI DOVRANNO ESSERE EFFETTUATE A CANCELLO CHIUSO e saranno efficaci solo nel ciclo successivo 15 ACCESSORI 15 1 Lampeggia...

Page 26: ...o normative per pi specifiche Le fotocellule non sono dunque pi obbligatorie in quanto la loro efficacia limitata Le fotocellule sono utili per poter comandare la riapertura del cancello mentre lo ste...

Page 27: ...il cancello ripetere il punto b 3 PER SOSTITUIRE UN CODICE PERSONALIZZATO a digitare il codice personale a 4 cifre il tasto 4 il nuovo codice a 4 cifre il tasto ENTER in basso al centro la tastiera em...

Reviews: