17
the passage.
Voluntarily interrupting their range you can keep the gate open.
The photocells must be installed to a maximum distance of 10 m between them, perfectly aligned. It is advisable
to position the photocell receiver so that it can not be disturbed by sunlight.
The photocells have a minimum lateral dimensions (only 2cm) and do not need to be recessed into the wall.
Must be fixed to the wall or on special columns and are suitable for outdoor use.
It is advisable to seal the outlet passage of the cables with silicone. see FIG.19 -22
Power supply: 12-24 V - d.c / a.c.
Connect to the electronic card following the wiring diagram of:
FIG.16 (photocell LASER Model SW7012 or 7012 ) for versions with card and CTH43
FIG.17 / A ( photocell model SW7120 or LASER7120 ) versions for use with card CTH46 powered by solar panel
FIG.17B (photocell LASER Model SW7012 or 7012 ) for versions with card CTH46 use on AC 230V -110V
15.5
KEYBoARD RADIo SW6500 - TASTY6700
Keyboard is a one channel rolling code radio
remote control
Without connecting cables used to activate the automation typing on a 4-digit personal code.
A rolling code signal will be transmitted to the equipment that will open the gate.
Can be installed inside and outside. Install in Max.10m from the control unit of the automation.
The device is outdoor but it is recommended if possible to install the keyboard in place protected from rain.
It is recommended to seal well the back of the keyboard before fixing it to the wall.
The keyboard comes with a standard code = 1111.
This code must be replaced with a personal code. Once you register your personal code the keyboard is
synchronized to the electronic automation in the same way in which you store the codes of other remote controls
(see paragraph 12).
Warning
: Write down your personal code and keep it in a safe place if you would record a code and if they forget
the figures, it would not be possible, for security reasons, reset the keyboard less than a new schedule at our
service center on resulting cost of intervention.
noTE
: If you type a wrong code 3 times, the keypad will enter in protection mode for 10 minutes. Wait 10 minutes
and enter the correct code.
WARnIng
1 - To AMEnD THE CoDE STAnDARD WITH A PERSonAL CoDE:
a) enter the standard code 1111 + push button 3 + New 4-digit code + ENTER button at the bottom center.
the keypad beeps to confirm the operation.
This deletes the standard code 1111.
Attention:
Before storing your personal code on the keyboard write it down and keep it in a safe place.
2 - To SEnD AnD SToRE THE RADIo SIgnAL automaton
a) on the central electronic automation: press P1
b) on the keypad dial the 4-digit personal code previously ENTER button at the bottom center.
Attention: The EnTER key must be pressed a few seconds.
The keypad will beep to confirm the operation. The red LED on the electronic board of your device will flash to
indicate the code has been stored.
The keyboard is synchronized with the central control automation. To operate the gate repeat step b )
3 - To REPLACE A PERSonALIZED CoDE:
a) enter the 4-digit personal code +
push button 4+ the new 4-digit code + ENTER button at the bottom center.
the keypad beeps to confirm the operation .
4 - To ADD A PERSonALIZED CoDE (without erasing the previously stored personal code):
a) enter the 4-digit personal code +
push button 3 + the new 4-digit code + ENTER button at the bottom center.
the keypad beeps to confirm the operation.