Section 4: Programming Options
No Activity Arm timer
This option is used to tell the iotega to arm in Away mode
when no zone activity is detected during the programmed
amount of time. The timer restarts when a Delay type zone is
restored.
Default:
0 Minutes (disables feature)
Valid range:
0 to 255 Minutes
High Traffic Shutdown
Activating this feature helps conserve battery power when
the system is disarmed by configuring a reporting timer.
When motion is detected, the device transmits an alarm to
the receiver and does not report any further events until the
timer expires. Any motion detected during the configured
period is reported onece the timer expires. No Delay causes
the device to report an alarm each time the detector is
tripped.
Default: Not Active
Valid
range:
Not Active, No Delay, 5 Second Delay, 15 Second Delay, 30
Second Delay, 1 Minute Delay, 5 Minute Delay, 10 Minute
Delay, 20 Minute Delay, 60 Minute Delay
4.6 Wireless Device Con-
figuration Options
This section describes programming options used to con-
figure supported wireless PowerG devices.
4.6.1 Wirefree Keypad Configuration
Options
The following sections describe programming options used
to configure the available wirefree keypad.
Keypad Label
This section is used to program a user-friendly name for the
keypad.
Default:
Blank
Valid range:
32 character ASCII
Keypad Partition Assignment
This section is used to program the partition that the wirefree
keypad is assigned to.
Default:
1
0 to 255
1, 2, Both
Fire Button Options
When this option is enabled, pressing and holding the Fire
[F] button on the wirefree keypad for 2 seconds triggers a
Fire alarm. The system sounds 3 beeps to acknowledge the
valid alarm and the siren sounds with a pulsing tone. An
alarm reporting code is transmitted to the central monitoring
station.
Default:
Enabled
Valid range:
Enabled/Disabled
Auxiliary Button Options
When this option is selected, pressing and holding the Aux-
iliary [A] button on the wirefree keypad for 2 seconds sends
an emergency alarm reporting code to the central mon-
itoring station. When the emergency reporting code is
received at the central monitoring station, the keypad beeps
10 times.
Default:
Enabled
Valid range:
Enabled/Disabled
Panic Button
When this option is selected, pressing and holding the Panic
[P] button for 2 seconds on the wirefree keypad sends an
emergency alarm reporting code to the central monitoring
station.
Default:
Enabled
Valid range:
Enabled/Disabled
Internal Buzzer Control
This option is used to set the volume level of the keypad’s
internal buzzer. The volume ranges from lowest (1) to
highest (15). Programming (0) turns off the buzzer.
Note:
Internal buzzer volume shall be at maximum setting
for UL/ULC.
Default:
7
Valid range:
0-15
Keypad Tamper
When this option is enabled, the wirefree keypad tamper
switch generates tamper alarms and restores when activ-
ated.
Default:
Disabled
Valid range:
Enabled/Disabled
- 30 -