Section 4: Programming Options
Default:
45 seconds (standard), 30 seconds (CP-01) (Note: Max. 45
seconds required for UL/ULC)
Valid
range:
30 to 255 Seconds (UL/ULC)
0 to 255 (standard)
Exit Delay
This value determines the length of time given to exit the
premises before the system becomes armed.
Default:
120 seconds (standard), 60 seconds (CP-01) (Note: Max.
45 seconds required for UL/ULC)
Valid
range:
45 to 255 seconds (UL/ULC)
0 to 255 (standard)
Closing Delinquency Delay
This value determines the time the alarm system delays
before transmitting a close delinquency event to the central
monitoring station.
Default:
30 Days
Valid range:
0 to 255 Days
Cross Zone Delay
If another zone with the Burglary Verification attribute
enabled is violated within the duration of this timer, a Burg-
lary Verified event is communicated and logged.
Default:
60 Seconds
Valid range:
0 to 255 Seconds
Quick Arm
When this option is enabled, the iotega can be armed
without entering an access code.
Note:
Quick arming cannot be initiated from the integrated
keypad.
Default:
Enabled
Valid range:
Enabled/Disabled
Quick Exit
When this option is enabled, users can temporarily bypass a
Delay 1 or Delay 2 zone to exit the premises when the sys-
tem is armed. Only one delay zone may be activated. Activity
on another delay zone initiates the appropriate alarm
sequence. If the delay zone is still open two minutes after
being bypassed, entry delay is initiated. If armed in Stay
mode, the automatic bypass on Stay/Away zones remains.
Note:
Quick Exit cannot be initiated from the integrated
keypad.
Default:
Disabled
Valid range:
Enabled/Disabled
Internal Siren
When this option is enabled, The iotega’s built-in siren activ-
ates during an alarm.
Default:
Enabled
Valid range:
Enabled/Disabled
Internal Buzzer
When this option is enabled, the iotega’s built-in buzzer
provides auditory feedback (e.g., key presses, door chime).
Default:
Enabled
Valid range:
Enabled/Disabled
Auto Arm
When this option is enabled, the iotega automatically arms
in away mode (stay/away zones active) at a programmed
time each day. The keypad emits three beeps to indicate the
system is armed. All arming inhibit features such as latching
tampers, AC inhibit, etc. also inhibit Auto Arming and send
the Auto Arm Cancellation code.
Default:
Disabled
Valid range:
Enabled/Disabled
Auto Arming by Schedule
This option is used to program the time of day each alarm
system partition automatically arms (in Away mode only). To
program an auto-arm time, select a day of the week and
then enter the time. At the programmed time, the keypad
buzzers beep to warn that automatic arming is in progress.
The siren also squawks once every 10 seconds during this
warning period if programmed to do so. When the warning
period is complete, the exit delay elapses and the system
arms in away mode.
Default:
0000
Valid range: 0000 to 2359 (4-Digit HH:MM) for each day of the week
Auto Arm Postpone Timer (for schedule only)
This option is used to program a time delay before the Auto
Arm sequence begins. Programming 0 cancels auto arming.
Default:
0 Minutes
Valid range:
0-255 minutes
- 29 -