P R O G R A M D E S C R I P T I O N S
37
5.22
Keypad Lockout
The panel can be programmed to ‘lockout’ keypads if a number of incorrect user code entries are made.
After the
Number of Invalid Codes Before Lockout
has been reached the panel will lock out the keypad
for the
Lockout Duration
and log the event to the event buffer. For the duration of the lockout the panel will
sound an error tone when any key is pressed.
Keypad Lockout will reset every hour.
To disable Keypad Lockout program the
Number of Invalid Codes Before Lockout
as [000].
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Number of Invalid Codes Before Lockout ...... Section [012]
Lockout Duration ............................................ Section [012]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Keypad Lockout Reporting Code ................... Section [338]
5.23
Keypad Blanking
If the
Keypad Blanking Option
is enabled the panel will turn off all lights on the keypads except the
backlighting of the keys if no key is pressed for 30 seconds.
The panel will turn the lights back on if entry delay begins or an audible alarm occurs. The lights will also
come on if a key is pressed or, if the
Code Required to Restore Blanking Option
is enabled, a valid User
Code is entered.
If the
Power Save Option
is enabled the panel will blank all keypad lights including backlighting when AC
power fails, in order to conserve the back up battery.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Keypad Blanking Option ................................ Section [016], Option [3]
Code Required to Restore Blanking .............. Section [016], Option [4]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Power Save Option ........................................ Section [016], Option [6]
5.24
Loop Response
The normal loop response time for all zones is 500 milliseconds. The panel will not consider a zone
violated unless it is violated for at least 500 milliseconds.
If
Zone 8 is Fast Loop Response
is enabled the loop response for zone 8 will be 40 milliseconds.
Typically this can be used for vibration type sensors.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Zone 8 is Fast Loop Response ..................... Section [013], Option [5]
5.25
Keypad Tampers
If the
Keypad Tampers Enable
option is selected the panel will display and transmit a
General System
Tamper
reporting code if any keypad is removed from the wall. When the keypad tamper is restored the
panel will transmit the
General System Tamper Restoral
reporting code. All keypads should be properly
installed and secured before enabling this option.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Keypad Tamper Enable .............................................. Section [016], Option [8]
General System Tamper Reporting Code ................. Section [338]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
General System Tamper Restoral Reporting Code ... Section [338]
5.26
LINKS1000 Cellular Communicator
The LINKS1000 cellular communicator can be used three different ways; as the sole communicator for the
panel, as a back up for either or both phone numbers or as a redundant back up to the land line
communicator (the panel will call both the land line and via the LINKS). A
LINKS Preamble
is
programmable for each phone number in the event that the land line number is local but the LINKS is
required to dial an exchange. When programming a LINKS Preamble, all unused digits must be
programmed with a hexa decimal “F”.
5.26.1
Using LINKS1000 as the Sole Communicator
The panel can be programmed to report only using the LINKS1000 cellular communicator when an event
occurs. To program this select only the LINKS1000 for the
Communicator Call Direction
Options for the
event. In addition the
Call LINKS
as well as
Land Line
option must also be enabled.
When the selected event occurs the panel will only attempt to call central station using the LINKS.