P R O G R A M D E S C R I P T I O N S
29
5.7.6
Priority/Emergency
The panel will transmit a
Keypad Fire Alarm
Reporting Code AND the
Keypad Fire Restoral
Reporting
Code when the Fire Keys on any keypad is pressed for two seconds.
The panel will transmit a
Keypad Auxiliary Alarm
Reporting Code AND the
Keypad Auxiliary Restoral
Reporting Code when the Auxiliary Keys on any keypad is pressed for two seconds.
The panel will transmit a
Keypad Panic Alarm
Reporting Code AND the
Keypad Panic Restoral
Reporting Code when the Panic Keys on any keypad is pressed for two seconds.
The panel will transmit a
Duress
Reporting Code any time either Duress Code is entered at any keypad. If
the panel is armed using the Duress Code the panel will also transmit a
Closing by Duress
Reporting
Code or if the panel is disarmed it will also transmit an
Opening by Duress
Reporting Code.
If PGM2 is being used for two wire smoke detectors
(See
) the panel will send
a
Two Wire Smoke Alarm
Reporting Code if a smoke detector goes into alarm. The panel will transmit the
Two Wire Smoke Alarm Restoral
Reporting Code when the zone is restored.
5.7.7
Maintenance
The panel will transmit a
Battery Trouble Alarm
Reporting Code when the backup battery drops below
11.5 V
DC
. The
Battery Trouble Restoral
Reporting Code will not be transmitted until the battery has been
charged over 12.5 V
DC
.
To prevent the panel from transmitting an
AC Failure Trouble Alarm
Reporting Code during short power
outages the panel will not send the signal unless AC power is lost for the amount of minutes programmed
for the AC Failure Communication Delay. The
AC Failure Trouble Restoral
Reporting Code will be
transmitted as soon as AC power is restored.
NOTE: If AC failure communications delay is programmed as 000, AC failure transmission will be
disabled.
A
Bell Circuit Trouble Alarm
Reporting Code will be transmitted immediately if an open condition is
measured on the Bell Output of the main panel. The
Bell Circuit Trouble Restoral
Reporting Code will be
transmitted as soon as the problem is corrected.
A
Fire Trouble Alarm
Reporting Code will be transmitted immediately when an open condition is
measured on any Fire type zone
(See
Section 5.1 “Zone Definitions”
). The
Fire Trouble Restoral
Reporting
Code will be transmitted as soon as the problem is corrected.
The
Auxiliary Power Supply Trouble Alarm
Reporting Code will be transmitted if the AUX output is
shorted. The AUX output control incorporates a fuseless design. When excessive current is drawn the
panel will automatically shut off the output. The panel will constantly check the AUX output and when the
excessive current draw is removed the panel will reset the output and transmit an
Auxiliary Power Supply
Trouble Restoral
Reporting Code.
A
TLM Trouble
Reporting Code can only be transmitted if a LINKS1000 Cellular Communicator is being
used
Section 5.26 “LINKS1000 Cellular Communicator”
). The panel will only transmit the signal after
the time programmed for the TLM Trouble Delay. The
TLM Restoral
Reporting Code will be transmitted
within 10 seconds of the problem being corrected.
A
General System Trouble
Reporting Code will be transmitted if the panel detects any of the following on
the PC5204 Power Supply/Output Module: AC Power Failure, Low Battery, AUX Output Trouble, Output #1
Supervisory trouble or the PC5400 is off-line. The
General System Trouble Restoral
Reporting Code will
be transmitted when all of the listed problems are corrected.
A
General System Supervisory Trouble
Reporting Code will be transmitted if any module goes missing
from the Keybus. If the module is a zone expander the panel will also transmit the
Zone Expander
Supervisory Alarm Trouble
Reporting Code. The panel will send a
General System Supervisory
Restoral
Reporting Code when the problem is corrected as well as a
Zone Expander Supervisory
Restoral
Reporting Code if the module is a zone expander.
5.7.8
Test Transmissions
The panel can be programmed to transmit a
Periodic Test Transmission
Reporting Code (See
System Test
Reporting Code
(See
) or a
LINKS1000 Test Transmission
Reporting Code
Section 5.26 “LINKS1000 Cellular Communicator”
5.7.9
Wireless Maintenance
The panel will transmit a
General Zone Low Battery Alarm
Reporting Code if a low battery condition is
indicated by a detector. The transmission of the trouble will be delayed by the number of days
programmed for
Zone Low Battery Transmission Delay
. The
General Zone Low Battery Restoral
Reporting Code will be transmitted when the problem is corrected. The specific zone that caused the
trouble will be stored to the Event Buffer.
The restoral will not be transmitted until all detectors indicate a good battery condition.