P R O G R A M D E S C R I P T I O N S
33
[16] LINKS1000 Support (PGM1 Only)
The PGM output will be used as a data wire to communicate phone number information for the LINKS1000
cellular unit.
[17] Away Armed
The PGM will activate when the system is armed with the Stay/Away zones activated.
[18] Stay Armed
The PGM will activate when the system is armed with the Stay/Away zones bypassed.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Main Board PGM Outputs ............................. Section [009]
PC5208 PGM Output Options ....................... Section [010]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
PC5204 PGM Output Options ....................... Section [011]
5.10.2
PGM Output Attributes
Each Programmable Output also requires the PGM Attributes to be programmed before they will operate
correctly. Attributes available are as follows:
Option [1] - ON Partition 1 Controls Event
OFF Partition 1 Does Not
Option [2] - ON Partition 2 Controls Event
OFF Partition 2 Does Not
Option [3] - ON Output Activates on Event
OFF Output Deactivates on Event
The Attribute Options for Option [09] System Trouble and [10] Latched System Event are
different. Refer to these options for more information.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
PGM1 (Main Board) Output Attributes .......... Section [141]
PGM2 (Main Board) Output Attributes .......... Section [142]
PC5208 PGM Output Attributes .................... Section [143] to [150]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
PC5204 PGM Output Attributes ..................... Section [151] to [154]
5.11
Telephone Line Monitor (TLM)
The panel will supervise the presence of the phone line and indicate a trouble condition if disconnected. If
TLM Enabled
is selected the panel will wait the
TLM Trouble Delay
time before indicating the trouble so
that a momentary interruption of the phone line will not cause a trouble condition.
The
TLM Trouble Only
or
Audible When Armed
option will allow you to select if the panel will indicate a
trouble condition at the keypad or indicate a trouble at the keypad when disarmed and activate the alarm
output when armed.
When the trouble condition is restored the panel can send a
TLM Restoral Reporting Code
. Any events
that occurred while the phone line was down will also be communicated.
If the LINKS1000 cellular communicator is being used the panel can be programmed to report a
TLM
Trouble Reporting Code
.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
TLM Enable/Disable ...................................... Section [015], Option [7]
TLM Trouble Only or Audible When Armed ... Section [015], Option [8]
TLM Trouble Delay ......................................... Section [370]
TLM Trouble Reporting Code ........................ Section [349]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
TLM Restoral Reporting Code ........................ Section [350]
5.12
Siren Supervision
The panel supervises the Bell output. If an open condition is detected or the fuse is blown the panel will
immediately indicate a trouble condition and beep the keypad twice every ten seconds to alert the owner
of the problem. The panel can send a
Bell Circuit Trouble
Reporting Code immediately. Once the
problem is corrected the panel can send a
Bell Circuit Trouble Restoral
Reporting Code.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Bell Circuit Trouble Reporting Code .............. Section [349]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Bell Circuit Trouble Restoral Reporting Code Section [350]