PowerSeries - PC1616/PC1832/PC1864
44
[375] System Maintenance Communicator Call Directions
[376] System Test Transmissions Communicator Call Directions
[377] Communication Variables
Default
003
I___
0
__I__
0
__I___
1
__I
Swinger Shutdown (Alarms and Rest)
001-014 Transmissions
003
I___
0
__I__
0
__I___
3
__I
Swinger Shutdown (Tampers and Rest)
001-014 Transmissions, 000=disabled
003
I___
0
__I__
0
__I___
3
__I
Swinger Shutdown (Maint and Rest)
001-014 Transmissions, 000=disabled
000
I___
0
__I__
3
__I___
0
__I
Communication Delay
000-255 seconds
030
I___
0
__I__
3
__I___
0
__I
AC Failure Communication Delay
001-255 minutes, 000=disabled
010
I___
0
__I__
1
__I___
0
__I
TLM Trouble Delay
No. of checks required - valid entries 002 - 255)
030
I___
0
__I__
3
__I___
0
__I
Test Transmission Cycle (land line)
001-255 days/minutes
†
030
I___
0
__I__
3
__I___
0
__I
For Future Use
007
I___
0
__I__
0
__I___
7
__I
Zone Low Battery Transmission Delay
000-255 days
030
I___
0
__I__
3
__I___
0
__I
Delinquency Transmission Cycle
001-255 days/hours
000
I___
0
__I__
0
__I___
5
__I
Communications Cancelled Window
001-255 minutes
†
Dependent on programming in section [702], option [3].
The values in gray GRAY are required for CP-01 compliant systems
For UL installations, the Entry Delay plus Communication Delay time must not exceed 60 seconds.
[378] Test Transmission Time of Day
Default
9999
I_______I_______I_______I_______I
Valid entries are 0000-2359 (9999 to disable)
[379] Periodic DLS Time of Day
Default
9999
I_______I_______I_______I_______I
Valid entries are 0000-2359 (9999 for Random, FFFF to disable)
[380] First Communicator Options
Section
Option 1
1st Telephone
Number (Def ON)
Option 2
2nd Telephone
Number (Def OFF)
Option 3
Not Used
(Def OFF)
Option 4
Not Used
(Def OFF)
Option 5
Alt Comm
(Def ON)
Options 6,7,8
Future Use
[375]
I________I
I________I
I________I
I________I
I________I
I________I
Section
Option 1
1st Telephone
Number (Def ON)
Option 2
2nd Telephone
Number (Def OFF)
Option 3
Not Used
(Def OFF)
Option 4
Not Used
(Def OFF)
Option 5
Alt Comm
(Def ON)
Options 6,7,8
Future Use
[376]
I________I
I________I
I________I
I________I
I________I
I________I
Opt
Def
ON
OFF
1
9
R
Communications Enabled
R
Communications Disabled
2
R
Restorals on Bell Time-out
9
R
Restorals Follow Zones
3
R
Pulse Dialing
9
R
DTMF Dialing
4
R
Switch to Pulse Dialing on 5th Attempt
9
R
DTMF Dial For All Attempts
5
R
3rd Telephone Number Enabled
9
R
3rd Telephone Number Disabled
6
R
Alternate Dial (1st & 3rd)
9
R
Call 1st Number, Back up to 3rd
7
R
For Future Use
9
R
8
R
Delinquency Follows Zone Activity (Hours)
9
R
Delinquency Follows Arming (Days)
WWW.DIYALARMFORUM.COM