Section 4 – Programming Descriptions
25
Section [703] Delay Between Dialing Attempts
Program the time the panel will wait between dialing attempts to transmit a reporting event to the central station.
Valid entries are
[001]
to
[255]
.
Section [800]-[851] Module Programming
The following program sections are used to program different modules that can be connected to the control panel. Refer to the respective
Installation Manual for installation and programming information
Section [801]:
PC5400 Printer Module Programming
Section [802]:
PC59xx VOX Module Programming
Section [803]:
Alternate Communicator Programming
Section [804]:
Wireless Programming
Section [805]:
PC5100 Addressable Programming
Section [851]:
T-Link Programming
Special Installer Instructions
Section [899] Template Programming
Selecting
[ ][8] [Installer Code] [899]
displays the current 5 digit template programming code. Refer to Section 3.1 Template Program-
ming on page 8 for details. Refer to Appendix C - Template Programming for a detailed description of available templates and correspond-
ing 5 digit codes.
Section [900]: Panel Version Displayed
Only available with LCD5500 or PK5500 keypads. The system will display the version of the control panel (for example, [0410] indicates
panel version 4.10).
Section [901]: Installer Walk Test
The system will turn Installer Walk Test
ON
. The Ready, Armed and Trouble LED’s will flash rapidly while the test is active. Every time a
zone is violated the system will activate the bell output for two seconds and log the event to the event buffer. To turn Installer Walk Test
OFF
enter Section
[901]
again. The system automatically terminates the test of there is no zone activity for 15 minutes.
Section [902]: Module Supervision Reset
All modules are automatically detected within one minute after being connected to the Keybus. Enter Section [902] to clear detected mod-
ules if a module is removed, if PC5108 jumpers are changed, or if a keypads slot assignments are programmed. The system will rescan the
Keybus to determine which modules are connected.
Section [903]: View Module Supervision
The keypad will display the modules detected by the system by turning on the associated zone light (LED keypads), flashing the numbers
(fixed-message LCD keypads) or displaying the modules detected in plain language (programmable LCD keypads). Refer to the chart below:
This feature requires a PK55xx or RFK55xx series keypad, v.1.1 or higher.
Indicator Light
(Zone)
Module
[01] to [08]
[09] to [14]
[15]
[16]
[17]
[18]
[19]
[20]
[21]
[22]
[24]
[26] to [29]
Keypad in Slot #1 to #8
PC5108 Zone Expander #1 to #6
PC5100 Module
PC5108 Zone Expander #7
PC5132 Module or RFK keypad with integrated wireless receiver
PC5208
PC5204 Module
PC5400 Module
PC59xx Module
Alternate Communicator
Escort5580 or Escort5580TC
PC5200 #1 to #4