PowerSeries - PC1616/PC1832/PC1864
28
5.2 Programming Worksheets
Shaded programming sections indicate minimum programming requirements
SIA FAR CP-01 defaults are indicated in gray text.
Keypad Partition /Slot and Function Key Programming
[000] Keypad
Enrollment
This must be done at each keypad requiring programming.
[0] Slot address [Valid entries are 0-8 for the partition, 1-8 for the slot. (e.g., to enroll a keypad in partition 3 and slot 1, enter (31)]
[1] Function Key 1 Assignment (Valid entries are 00-33)
[2] Function Key 2 Assignment (Valid entries are 00-33)
[3] Function Key 3 Assignment (Valid entries are 00-33)
[4] Function Key 4 Assignment (Valid entries are 00-33)
[5] Function Key 5 Assignment (Valid entries are 00-33)
Function Key Options:
[001]-[004] Zone Definitions
00 Not used
11 [*][5] Access Code Programming
22 Global Disarming
01 Select Partition 1
12 [*][6] User Functions
23 Bypass Recall
02 Select Partition 2
13 Command Output #1 [*][7][1]
24 Recall Bypass Group
03 Stay Arm
14 Command Output #2 [*][7][2]/Sensor Reset
25 For Future Use
04 Away Arm
15 Global Stay Arming
26 Time and Date
05 [*][9] No-Entry Arm
16 [*][0] Quick Exit
27 Select Partition 3
06 [*][4] Chime On / Off
17 [*][1] Reactivate Stay/Away Zones
28 Select Partition 4
07 [*][6][——][4] System Test
18 Global Away Arming
29 Select Partition 5
08 [*][1] Bypass Mode
19 Command Output 3 [*][7][3]
30 Select Partition 6
09 [*][2] Trouble Display
20 For Future Use
31 Select Partition 7
10
[*][3] Alarm Memory
21 Command Output 4 [*][7][4]
32 Select Partition 8
33 Activate Local PGM
Partition/
Slot
[20] Zone
Assigned
Key 1
Key 2
Key 3
Key 4
Key 5
ICON / LED Defaults
11
00
03
04
06
14
16
Full Message Defaults
18
00
03
04
06
14
16
KEYPAD 1
00
KEYPAD 2
00
KEYPAD 3
00
KEYPAD 4
00
KEYPAD 5
00
KEYPAD 6
00
KEYPAD 7
00
KEYPAD 8
00
00
Null Zone (Not Used)
12
24 Hour Holdup*
25
Interior Delay*
01
Delay 1*
13
24 Hour Gas*
26
24 Hour Non-alarm*
02
Delay 2*
14
24 Hour Heating*
29
Auto Verified Fire
03
Instant*
15
24 Hour Auxiliary*
30
Fire Supervisory
04
Interior*
16
24 Hour Panic*
31
Day Zone*
05
Interior, Stay/Away*
17
24 Hour Emergency*
32
Instant Stay/Away*
06
Delay, Stay/Away*
18
24 Hour Sprinkler*
35
24-hour Bell/Buzzer
07
Delayed 24 Hour Fire (Hardwired)**
19
24 Hour Water*
36
24 Hour Non-Latching Tamper Zone
08
Standard 24 Hour Fire (Hardwired)
20
24 Hour Freeze*
37
Night Zone
09
24 Hour Supervisory
21
24 Hour Latching Tamper*
87
Delay 24 Hour Fire (Wireless/Addressable)**
10
24 Hour Supervisory Buzzer*
22
Momentary Keyswitch Arm*
88
Standard 24 Hour Fire (Wireless/
Addressable
)**
11
24 Hour Burglary*
23
Maintained Keyswitch Arm*
*For burglary applications only
** For residential fire applications only
WWW.DIYALARMFORUM.COM