PowerSeries - PC1616/PC1832/PC1864
20
Section [379] Periodic DLS Time of Day
Programs the time the system will auto-call DLS. Program 4 digits –
[HH][MM]
using military standard. For a DLS auto-call at 11:00 pm,
program data
[23][00]
). Valid entries are
[00][00]
to
[23][59].
Programming
[99][99]
will select a random time,
[FF][FF]
will disable it.
Please refer to the
PC 1616/1832/1864 Reference Manual
for a complete description of Periodic DLS.
Section [380] First Communicator Option Code
Section [381] Second Communicator Option Code
Section [382] Third Communicator Option Code
Option
Description
[1]
ON:
the system communicator is enabled.
OFF:
the communicator is disabled.
[2]
ON:
the system transmits alarm restorals if the zone is restored and the bell has timed out.
OFF:
the system transmits alarm restorals
immediately when the zone is restored.
[3]
ON:
the panel uses rotary (pulse) dialing.
OFF:
the panel uses touchtone (DTMF) dialing
[4]
ON:
the panel will switch from touchtone dialing to rotary dialing after the 4th failed attempt to communicate.
OFF:
the panel will use DTMF dialing for all dialing attempts.
[5]
ON:
the system uses the Third Phone Number to back up the First Phone Number.
OFF:
the Third Phone Number is disabled.
[6]
ON:
the system alternates between the First Phone Number and Third Phone Number when attempting to report an event.
OFF:
the panel will dial the First Phone Number for the programmed number of attempts, then switch to the Third Phone Number.
[7]
For future Use
[8]
ON:
the Delinquency feature follows zone activity.
OFF:
the Delinquency feature follows arming.
Option
Description
[1]
ON:
the keypad beeps 8 times after successfully transmitting the
Opening After Alarm
reporting event.
OFF:
the keypad does not beep.
[2]
ON:
the bell output squawks 8 times after successfully transmitting the
Opening After Alarm
reporting event.
OFF:
the bell output does
not activate.
[3]
ON:
the system uses programmed reporting codes when transmitting using the SIA format.
OFF:
the system automatically generates all reporting codes transmitted.
[4]
ON:
the system beeps the keypad 8 times after successfully transmitting a
Closing
reporting event.
OFF:
the keypad does not beep.
[5]
ON:
the system requests a
Listen in/Two-way
session the next time it calls the
1st/3rd Phone Number
when the PC59xx transmits a
request.
OFF:
the system ignores the request from the PC59xx.
This Option is used with PC59xx series modules.
[6]
ON:
the system requests a
Listen in/Two-way
session the next time it calls the
2nd Phone Number
when the PC59xx transmits a request.
OFF:
the system will ignore the request from the PC59xx.
This Option is used with PC59xx series modules.
[7]
ON:
the system uses
Contact ID format
programmed reporting codes when transmitting reporting codes.
OFF:
the system automatically generates all reporting codes transmitted.
[8]
ON:
the system will follow ULC Communication Priority
OFF:
the system will follow standard communications priority.
Option
Description
[1]
ON:
the system will use the digit
[5]
as the first digit of the Partial Closing reporting code when transmitting Contact ID reporting codes.
OFF:
the system will use the digit
[4]
as the first digit of the Partial Closing reporting code when transmitting Contact ID reporting codes.
[2]
ON:
the system will transmit all alarms during Walk Test.
OFF:
the system will not report alarm events during Walk Test.
WWW.DIYALARMFORUM.COM