Section 4 – Programming Descriptions
23
PGM Output Option [31]
PGM Output Option [32]
PGM Output Option [29] and [35]-[41]
Section [551] to [564] PGM Partition Assignment
These sections are used to customize the operation of the PGM outputs (Section
[551]
for PGM 1, Section
[552]
for PGM 2 etc.). Turn on the
correct option in the correct section to assign the PGM output to a specified partition. PGM outputs can be assigned to more than one parti-
tion. For PGM outputs that are considered ‘system’ outputs (e.g.,Trouble output), programming in these sections will not affect the operation
of the PGM output.For Zone Follower PGM types 29, 35-41 these sections are used to assign specific zones to the PGM.
Any one Command Output PGM type cannot be assigned to more then one partition.
[3]
ON:
PGM output activates if a Panic Alarm occurs.
[4]
ON:
PGM output activates if a Medical Alarm occurs.
[5]
ON:
PGM output activates if a Supervisory Alarm occurs.
[6]
ON:
PGM output activates if a Priority Alarm occurs.
[7]
ON:
PGM output will activates if a 24-Hour Hold-Up Alarm occurs.
[8]
ON:
the PGM output activates for the time programmed for the PGM Output Timer.
OFF:
the PGM output will latch until a valid user code
is entered.
Option
Description
[1]
ON: PGM output activates if a Fire Alarm occurs.
[2]
ON:
PGM output activates if a Panic Alarm occurs.
[3]
ON:
PGM output activates if a Burglary Alarm occurs.
[4]
ON:
PGM output activates if an Opening/Closing occurs.
[5]
ON:
PGM output activates if a a zone is automatically bypassed.
[6]
ON:
PGM output activates if a Medical Alarm occurs.
[7]
ON:
PGM output will activates if a confirmed alarms occurs and Police Code occurs.
[8]
ON:
the PGM output is active when the selected condition is true.
OFF:
the PGM output will latch until a valid user code is entered
Option
Description
[1]-[7]
For Future Use
[8]
ON:
the PGM will activate for the duration programmed in PGM Output Timer.
OFF
: the PGM will activate when an Opening After Alarm
occurs and will deactivate when a valid access code is entered.
Option
Description
[1]-[2]
For Future Use
[3]
ON:
the PGM will switch to ground when the event occurs.
OFF:
the PGM will switch to open when the event occurs.
[4]-[7]
For Future Use
[8]
ON:
AND logic is selected, all zones that are enabled must be violated before the PGM will activate.
OFF:
OR Logic is selected, only one
violated zone is required to activate the PGM. All zones must be restored to turn it OFF.
Zones are assigned to this PGM in the PGM Partition Assignment Section
[551]
-
[564]