PowerSeries - PC1616/PC1832/PC1864
30
Programmable Output Options
01
Residential Burglary and Fire Bell Output
18
Stay Armed Status
36
Zone Follower Output (Zones 17-24
02
For Future Use
19
Command Output #1 ([*][7][1])
37
Zone Follower Output (Zones 25-32)
03
Sensor Reset [*][7][2]
20
Command Output #2 ([*][7][2])
38
Zone Follower Output (Zones 33-40)
04
2 Wire Smoke Support (PGM 2 only)
21
Command Output #3 ([*][7][3])
39
Zone Follower Output (Zones 41-48)
05
System Armed Status
22
Command Output #4 ([*][7][4])
40
Zone Follower Output (Zones 49-56)
06
Ready To Arm
23
24 Hour Silent Input
41
Zone Follower Output (Zones 57-64)
07
Keypad Buzzer Follow Mode
24
24 Hour Audible Input
08
Courtesy Pulse
25
Delayed Fire and Burglary Output
09
System Trouble Output (with Trouble options)
26
Battery Test Output
10
System Event [Strobe (with Event options)]
28
Holdup Output
11
System Tamper (all sources: zones, keypad, modules)
29
Zone Follower Output (Zones 1-8)
12
TLM and Alarm
30
Partition Status Alarm Memory
13
Kissoff Output
31
Alternate Communicator
14
Ground Start Pulse
32
Open After Alarm
15
Remote Operation (DLS-3 Support)
33
Bell Status and Programming Access Output
16
For Future Use
34
Away Armed with no Zone Bypassed Status
17
Away Armed Status
35
Zone Follower Output (Zones 9-16)
[010] PGM3 to PGM10 Output Programming (Main Panel/PC5208)
Program PGM Option Attributes in sections [501] - [514]. Program PGM partitions in sections [551] - [564]
Default
Default
01
I_______I_______I
PGM 3 (main panel/PC5208)*
01
I_______I_______I
PGM 7 (PC5208)
01
I_______I_______I
PGM 4 (main panel/PC5208)*
01
I_______I_______I
PGM 8 (PC5208)
01
I_______I_______I
PGM 5 (PC5208)
01
I_______I_______I
PGM 9 (PC5208)
01
I_______I_______I
PGM 6 (PC5208)
01
I_______I_______I
PGM 10 (PC5208)
These two sections allow you to program both PGM3 and PGM4 on the main panel, and the first two PGM outputs on the PC5208. If you use
both the main panel and the PC5208 outputs, PGM3 will work the same as the first PC5208 output, and PGM4 will work the same as the sec-
ond PC5208 output.
[011] PGM 11 to PGM 14 Output Programming (PC5204)
Program PGM Option Attributes in sections [501] - [514]. Program PGM partitions in sections [551] - [564]
Default
Default
01
I_______I_______I
PGM 11
01
I_______I_______I
PGM
13
01
I_______I_______I
PGM 12
01
I_______I_______I
PGM 14
Other System Options
[012] Keypad Lockout Options
If Keypad Lockout is active, the panel cannot be disarmed with a keyswitch.
Default
000
I_______I_______I_______I
Number of Invalid Codes Before Lockout (001-255 codes)
000
I_______I_______I_______I
Lockout Duration (001-255 minutes)
[006] Installer’s Code
[007] Master Code
[008] Maintenance Code
Default
Default
Default
5555
I_______I_______I_______I_______I
1234
I_______I_______I_______I_______I
AAAA
I_______I_______I_______I_______I
[009] PGM1 and PGM2 Output Programming (Main Panel)
Program PGM Option Attributes in sections [501] - [514]. Program PGM partitions in sections [551] - [564]
PC1616 and PC1832 have 2 onboard PGMs (PGM 1 and 2). PC1864 has 4 onboard PGMs (PGM 1-4)
Default
Default
19
I_______I_______I
PGM 1
10
I_______I_______I
PGM 2
Output types [03] and
[20] cannot be used
together on the same
system.
WWW.DIYALARMFORUM.COM