Section [016] Fourth System Option Code
Section [017] Fifth System Option Code
Section [018] Sixth System Option Code
[8]
ON:
the system activates the bell output if a telephone line trouble is detected while the system is armed.
OFF:
the system activates
the keypad buzzer trouble tone.
Option
Description
[1]
ON:
the system supervises the AC input and displays a trouble if a failure is detected.
OFF:
AC Input is not supervised.
[2]
ON:
the trouble light will flash when an AC trouble is detected.
OFF:
the trouble light turns on, does not flash.
[3]
ON:
the keypad blanks (no indicator lights) if a key is not pressed for 30 seconds.
OFF:
the keypad does not blank.
[4]
ON:
a valid user code must be entered to restore normal keypad operation after the blanking.
OFF:
pressing any key will return the
keypad to normal operation.
[5]
ON:
keypad backlighting enabled.
OFF:
keypad backlighting disabled.
[6]
ON:
the system temporarily enables the Keypad Blanking feature if an AC failure is detected (to preserve the back up battery).
OFF:
the system will operate as normal.
[7]
ON:
the keypad turns
ON
the Bypass light if zones are bypassed while the system is armed.
OFF:
the Bypass light turns
OFF
when
the system is armed.
[8]
ON:
the system supervises keypad tampers.
OFF:
the system does not supervise keypad tampers.
Option
Description
[1]
ON:
the system does
NOT
associate wireless keys to user codes.
OFF:
the system will assign user code 17 to wireless key #01, user
code 18 to wireless key #02 etc. If the wireless key is used to arm or disarm, the system will report the Opening or Closing for the
associated User Code.
[2]
ON:
the system logs an RF Jam trouble condition if the condition is present for 5 minutes.
OFF:
the system logs the trouble
condition after 30 seconds.
[3]
ON:
the keypads beep if an RF Jam trouble is detected.
OFF:
the trouble is not annunciated via the keypad buzzer.
[4]
ON:
the Double Hit feature will be enabled. Two violations from the same zone within the Cross Zone Timer will be considered a
valid Police Code or Cross Zone event. The system will report the event and log it to the event buffer.
OFF:
two alarms from the same zone is not a valid Police Code or Cross Zone event.
[5]
ON:
the system logs and communicates a
Late-To-Close
event when it auto-arms at the programmed time (not if auto arming was
caused by the No-Activity Arming feature).
OFF:
the system does not transmit or log a
Late-To-Close
event.
[6]
ON:
enables the Daylight Savings automatic clock adjustment feature.
OFF:
the system does not automatically adjust the clock for
Daylight Savings.
[7]
For Future Use
[8]
ON:
the system only squawks the bell output when the system is armed in the Away mode.
OFF:
the system squawks the siren
when the system is armed in any mode. (See Section [14]).
Option
Description
[1]
ON:
the system only transmits a Test Transmission reporting code if no other event was transmitted to the central station during the
programmed time.
OFF
the system always transmits a Test Transmission reporting code as programmed.
[2]-[4]
For Future Use
WWW.DIYALARMFORUM.COM