PowerSeries - PC1616/PC1832/PC1864
16
Section [023] Tenth System Option Code
Section [030] Fast Loop Response
This section is used to determine the Loop Response Time for the main panel zones.
Section [101] to [164] Zone Attributes
These sections are used to customize the operation of the zones. There are 9 toggle options in each Section:
[5]
For Future Use
[6]
Refer to the
PC1616/PC1832/PC1864 Reference Manual
for
RF Delinquency
details.
[7]
Future Use
[8]
ON:
When the system is armed in Stay mode, during the Exit delay, the system will sound 1 beep every 3 second.
OFF
: When the system is armed in Stay mode, the system will be silent during the Exit delay.
Option
Description
[1]
ON:
the keypad
[F]
emergency key will only beep three times to acknowledge the button has been pressed. The system will not
activate the bell output.
OFF:
the system will activate the bell output and beep the keypad.
[2]
Refer to the
PC1616/PC1832/PC1864 Reference Manual
for
200 Baud Open/Close Identifier
details.
[3]
ON:
the system will only transmit the Test Transmission reporting code if the system is armed at the time the system is programmed
to report the event.
OFF:
the system will always report the Test Transmission reporting code at the programmed time.
[4]
ON:
the system changes the Test Transmission Reporting Cycle Time from
Days
to
Hours
.
OFF:
the Test Transmission Reporting
Cycle Time is in
Days
.
[5]
ON:
the user cannot switch from Away Arm mode to Stay Arm mode using the function keys.
OFF:
the user can switch arming
modes.
[6]
ON:
the system disconnects a listen in/two-way session if a new event occurs.
OFF:
the system does NOT disconnect. New events are transmitted only after the session is terminated.
[7]
ON:
the system does
NOT
activate the keypad buzzer for any trouble condition (excluding Fire Troubles).
OFF:
the system
annunciates troubles via the keypad buzzer (two beeps every 10 seconds) normally.
[8]
ON:
Keyswitches will always arm in away mode.
OFF:
Keyswitches will arm in away mode if an entry/exit zone is violated during
exit delay.
ON:
the loop response time will be 36 mS.
OFF:
the loop response time will be 400 mS.
Option
Description
[1]
ON:
alarms are audible (bell output).
OFF:
alarms are silent.
[2]
ON:
the bell output is steady (burglary).
OFF:
the alarm output pulses (fire).
[3]
ON:
a zone violation or restoral will activate Chime.
OFF:
Chime is not activated.
[4]
ON:
the user can manually bypass the zone using the
[ ][1]
command.
OFF:
the zone cannot be manually bypassed.
[5]
ON:
the partition can be armed even if the zone is violated (the zone will not affect the Ready status).
OFF:
the zone must be
secure before arming.
[6]
ON:
the system shuts down alarm reporting after the programmed number of alarms have occurred.
OFF:
the panel will always
report the event if an alarm occurs.
[7]
ON:
the system delays reporting the event for the time programmed for the Transmission Delay time.
OFF:
the panel
immediately transmits the reporting event when an alarm is detected.
[8]
ON:
the zone is a wireless or addressable device.
OFF:
the zone is a hardwire zone (main panel, zone expander or keypad zone).