21
English
A p o l l o
80 -
i n s t r u c t i o n
f o r
i n s tA l l At i o n
F. Electronicskeepsparkingwhen
thepilotburnerisburning
1. Receiverisdamaged.
1. Replacethereceiverandconfirm/change
thecode(solution1atA)
G. Pilotburnerisburningbut
themagneticvalvecloses
afterapprox.10secondsor
whentheappliancegetstoo
hot
1. Thermocouple1doesnot
function.
2. Batteries(almost)dead
1.1 Measurethevoltagewithadigitalmulti-
meter,settomVrange,byconnectingthe
wirestothecableterminal.Thecableter-
minalisontheoutside,rightnexttothe
magneticnut,see2:Batteries(almost)
dead(see
Photo 17
).Thevoltageshould
beatleast5mVwithin20seconds.This
mustnotbeanylowerwhentheappli-
anceishot.
Ifthevoltageistoolowthen
-thethermocoupleshouldbemovedso
thatitisintheflamemore,or
-thethermocoupleshouldbereplaced.
1.2 Checkthesizeofthepilot.
Adjustthepilotifitistoolow.
1.3 Checkthewiringbetweenthethermocou-
pleandthereceiver.
Replacethewiringifnecessary.
2. Replacethebattery.
H. Thereareshortbleepsbut
nosparksandisnosound
/tickingcanbeheardofthe
magnetopeningthevalve
1. Batteries(almost)dead
1. Replacethebatteries.
!N.B.
Avoid short circuits between the batte-
ries and metal parts of the appliance.
I. Pilotburnerisonbutthereis
nogasflowtothemainburner
1. ButtonAissettoMAN.
2. Applianceissettopilot
mode.
3. Pre-pressureistoolow.
4. Magneticvalveisdamaged.
1. SwitchbuttonAonthegascontrolblock
toON,see
Photo 14
2. Increasetheflameheightbypressing
/
t
button
ontheremotecontrol.
3. Testthepre-pressure
Contactthepowercompanyifnecessary.
4. Replacethegascontrolblock.
J. Mainburnersignites,butgo
outagainafterapprox.22
seconds.
1. Wiringofthermocouple2is
loose.
2. Wiresofthermocouple2
havebeencross-connected.
3. Short-circuitinthewiringof
thermocouple2.
4. Brokenwireinthewiringof
thermocouple2.
5. Thermocouple2isdirty.
6. Thermocouple2isnotposi-
tionedcorrectlyintheflame
(seefig.23.)
7. Thermocouple2isdefective.
8. Receiverisdefective.
1. Connectthewiringproperly.
2. Connectthewiringproperly.
3. Replacewiring.
4. Replacewiring.
5. Cleanthethermocouple.
6. Positionthethermocouplecorrectlyin
theflame.
7. Checkthevoltageacrossthermocouple2
justbeforethemainburnergoesout.
Ifthevoltageislowerthan1.8mV,re-
placethermocouple2.
8. Checkthevoltageacrossthermocouple2
justbeforethemainburnergoesout.
Ifthevoltageishigherthan1.8mV,
replacethereceiver.
UK