3
English
A p o l l o
80 -
i n s t r u c t i o n
f o r
i n s tA l l At i o n
1.
Introduction
TheApollo80isaclosedatmosphericgasheatingappliance.Aclosedappliancedoesnotextractthecombustion
airfromthelivingenvironment,butfromoutside.Thisisdonebymeansofacombinedfluegasdischargesystem
/combustionairsupplysystem.Inthisconcentricsystem,theouterpipefunctionsastheairsupplyandtheinner
pipefunctionsasthefluegasdischarge.
Thesafeoperationoftheapplianceisguaranteedbytheuseofasecondthermocouplefittedtothemainburner.
Thissystemcanbeinstalledthroughthewallorthroughtheroof.
Theapplianceisbuiltinachimneybreast.Forthis,DRUhasanumberofchimneybreastsinitsrange.Inorder
toreachaproperheatdischarge,thechimneybreastmustbeventilated.DRUisabletosupplyvariousventilation
elements.
Theapplianceissuppliedwithawireless,batterypoweredremotecontrol.
2. EC Declaration of Conformity
WeherebydeclarethatthedesignandconstructionofthedecorativegasheatingappliancemarketedbyDRUcon-
formswiththeessentialrequirementsoftheGasApplianceDirective.
Thisdeclarationwillberenderedinvalidshouldtheappliancebealteredinanywaywithoutthewrittenconsentof
DRU.
Product:
Decorative gas heating appliance
Type:
Apollo 80
ApplicableECDirectives:
90/396/EEC
Applicableharmonisedstandards:
NEN-EN-613, NEN-EN-613/A1
In-housemeasuresguaranteethatseriallyproducedappliancesalwaysconformwiththeessentialrequirementsof
thecurrentECDirectivesandtheapplicablestandards.
R.Gelten
Generalmanager
DRUVERWARMINGB.V.
Postbus1021,6920BADuiven
Ratio8,6921RWDuiven
www.dru.nl
3.
SAFETY
3.1 General
N.B.
- Please read this chapter on safety carefully before commencing installation or maintenance;
- Always observe universal regulations and the precautionary measures / safety instructions in this manual.
3.2 Regulations
Theapplianceshouldbeinstalledincompliancewithcurrentnational,localandconstructional(installation)regulations.
3.3 Precautionary measures / safety instructions regarding installation
Observethefollowingprecautions/safetyregulationsprecisely:
➠
You may only install and/or service this appliance if your are a qualified installer skilled in installing decorative gas fires;
➠
do not adjust the appliance in any way;
➠
Non-combustible and heat-resistant materials should be used to construct the chimney breast, its rear wall, the inte-
rior and the top of the chimney breast;
➠
the minimum internal dimensions required for the chimney breast must be taken into account;
➠
the chimney breast should be ventilated by vents with total free vent area of 200 cm
2
;
➠
only use the flue /combustion air supply systems supplied by DRU;
➠
use the wall brackets supplied to mount the appliance;
➠
do not install the appliance flat against the back wall;
➠
leave the space between the feet free;
➠
do not cover and/or pack the appliance with an insulating blanket or any other material;
➠
Keep combustible objects and/or materials at a minimum distance of 500 mm from the appliance.
➠
only use the log set supplied;
➠
arrange the logs exactly as described;
➠
leave a space around the pilot burner;
➠
make sure thermocouple 2 and the space around it are kept free;
➠
avoid any dirt in the gas pipes and connections;