2.4.11 GPIO-Interface
The GPIO interface (HD-SUB 25, female) provides for the connection of alarm detectors. For this use
the GPIO connector set which can be obtained as an accessory from your system integrator or
DResearch. Up to 6 sensors (digital inputs, optocoupler inputs) and 4 digital switch outputs (relays)
can be connected.
Pin Name
Description
Pin
Name
Description
1
OUT2-
COMMON
Relay output 2 – common contact
14
---
Not used!
2
OUT2-NC
Relay output 2 – normally closed
(Opener)
15
---
Not used!
3
OUT2-NO
Relay output 2 – normally open
(Closer)
16
---
Not used!
4
OUT1-
COMMON
Relay output 1 – common contact
17
OUT1-NO
Relay output 1 – normally open
(Closer)
5
OUT1-NC
Relay output 1 – normally closed
(Opener)
18
Input 8 -
Digital input 8 - negative
6
Input 8 +
Digital input 8 - positive
19
Input 7 -
Digital input 7 - negative
7
Input 7 +
Digital input 7- positive
20
Input 6 -
Digital input 6 - negative
8
Input 6 +
Digital input 6 - positive
21
Input 5 -
Digital input 5 - negative
9
Input 5 +
Digital input 5 - positive
22
Input 4 -
Digital input 4 - negative
10
Input 4 +
Digital input 4 - positive
23
Input 3 -
Digital input 3 - negative
11
Input 3 +
Digital input 3 - positive
24
Input 2 -
Digital input 2 - negative
12
Input 2 +
Digital input 2 - positive
25
Input 1 -
Digital input 1 - negative
13
Input 1 +
Digital input 1 - positive
Note: The digital inputs are internally optocoupler isolated. The negative contacts (PIN 18-25) refer
to the corresponding positive input (PIN 6-13)! The individual negative inputs are not connected
via a bridge!