26 of 95
Reference Manual ATOM one SSM500
7.9 link_settings <flag>
Note:
This command is only available in the ATOM one SSM500
Trigger mode
.
By default the live and playback chain can be configured independently (split mode). By
enabling
link_settings
you can configure the settings of both chains simultaneously,
regardless of the current setting of the
out
command and without having to call the
copy_settings
command.
Flag
Function
0 (reset)
Settings of Live and Playback chain are not linked (split mode)
1
Settings of Live and Playback chain are linked (linked mode)
When enabled the following commands will be executed for both chains:
•
System Commands (chapter 8):
◦
pq_max_brightness
◦
log_mode
•
Video Commands (chapter 10):
◦
wb_preset (for the playback chain, it does not apply the R/G/B gains of the
preset, but set them to x1)
◦
black_red, black_green, black_blue
◦
flare
◦
filter_enable, filter_detail, filter_denoise
◦
color_conv, sdi_range, sdi_white, sdi_black color_cross, color_cross_offset
◦
post_cont, post_bright, post_sat, post_hue
◦
black_master
◦
mcc, mcc_opmode, mcc_set, mcc_blink
•
Knee Function (chapter 12):
◦
knee
•
Look-up Table Management (chapter 13):
◦
lut_preset, lut_enable
◦
lut_sample, lut_sample_red, lut_sample_green, lut_sample_blue,
lut_sample_master
◦
lut_interpolate, lut_interpolate_red, lut_interpolate_green, lut_interpolate_blue
◦
lut_reset, lut_reset_red, lut_reset_green, lut_reset_blue, lut_reset_master
◦
lut_fun_rec709, lut_fast_gamma, lut_mode, lut_fixed_mode