45 of 95
Reference Manual ATOM one SSM500
be programmed with the
genlock_offset
command.
The current genlock status can be checked with the
genlock_status
command. This will also show whether
crosslocking is enabled.
2
Output / Master In this mode the genlock connector will become an output with
a tri-level sync signal.
The output mode depends on the current video mode and can
be changed at any time.
Note: The genlock output does not have a strong driver
strength.
It is made for testing purposes only. It works good for
short cables and can be used to simply connecting two
cameras. We recommend to use external tri-level syn signals
for genlock purposes.
10.5.1
Status LED
The Status LED shows the status of the genlock.
Value
Status
Note
Yellow
Wait for lock
May take up to 10 seconds
Red
Fail to lock, or lock lost The camera will re-lock as soon as the
input signal is valid. Locking can also be
triggered by changing the video mode or
genlock settings.
Blue
Locked
Defaut state of system
10.6 genlock_status
Use this command to query the current genlock status, additionally the status is also
shown on the OLED screen. The following values can be returned:
Value
Status
Comment
0
OK
Genlock is disabled (no lock required) or Genlock is enabled
and the lock was successful.
1
Crosslock
Genlock is enabled and the lock was successful, but
crosslock was enabled because the supplied sync signal
does not match the video mode.
This is not an error, just an information. If you do not want to
use crosslocking make sure that the supplied sync signal