95 of 95
Reference Manual ATOM one SSM500
pos0...8
Iris aperture position
value
Range 0...100.
The table has to be transmitted sorted from the highest to the lowest aperture value. All
unused (not active) points in the table should be omitted, or set to zero.
Example:
# Transmit the following table to the camera:
F-Stop
16
11
8
5.6
4
2.8
2
1.4
0
Position
90
84
79
72
62
49
29
0
0
Active
Active Active Active Active Active Active Active Active Not
Active
iris_table 160 90 110 84 56 72 40 62 28 49 20 29 14 0 0 0
18.15
filter_pos <position>
This command can be used to determine and set the current filter position. The command
works like the focus position command described in chapter 18.6.
18.16
filter_setup <speed> <stepMode> <torque>
This command can be used to control the filter motor speed, step mode and torque. The
command works like the focus settings command described in chapter 18.8.