DragonWave Inc.
102
Horizon Compact Plus Release 1.0.1
Wireless Ethernet Product User Manual
– Volume 2
The CLI command
set network
management interface p3
(could
be p2, p1, or p4 if the management
is connected to corresponding port)
configures the Horizon Compact
Plus to only accept management
traffic on p3 of the system
connected through the network to
the management station (PC). Full
management of the near end is
possible. Management of the far
end unit over the radio link is not
possible.
The CLI command
set network
management
interface
dp3
(could be dp2, dp1, or dp3 if the
management is connected to p2,
p1, or p3 respectivey) applied at
both ends of the link
,
configures
the system to carry in-band
management traffic across the
radio link to the far end, allowing
full management of both ends of
the link. Note that there is no
physical
connecton
to
the
management overlay network on
the far end of the link.
When both the near and far end
Horizon Plus units are configured
with
the
same
out-of-band
management
port
(p3
in
this
example) and both are connected to
the management overlay network,
then a network loop is established,
causing network failure.