Threshold Alarms
73
Horizon Compact Plus Release 1.0.1
Wireless Ethernet Product User Manual
– Volume 2
Required Action
Steps
View RSL threshold alarm
settings
Displays the current settings for the Threshold Alarm for the Receive
Signal Level (RSL). Once the RSL Value Threshold is reached and
continues for the Time Limit duration then an alarm is raised.
Sequence:
get rsl threshold
press Enter
The system responds:
RSL threshold set to : <rsl value> dbm
RSL timelimit set to : <timelimit> secs
Where
<rsl value>
is the current RSL value in integers, given in dBm.
<timelimit>
is the current time limit that the condition must occur
before the alarm is raised. Timelimit is in integers, given in number
of seconds
Configure RSL threshold
alarm settings
Sets the current settings for the Threshold Alarm for the Receive
Signal Level (RSL). Once the RSL Value Threshold is reached and
continues for the Time Limit duration then an alarm is raised.
Sequence:
set rsl threshold <rsl value> <timelimit>
press Enter
Where
<rsl value>
is the desired RSL value in integers, given in dBm.
<timelimit>
is the desired time limit that the condition must occur
before the alarm is raised. Timelimit is in integers, given in number
of seconds
The system responds:
RSL threshold set to : <rsl value> dbm
RSL timelimit set to : <timelimit> secs
View snr threshold
Returns the current signal to noise ratio alarm threshold.
Sequence:
get snr threshold
press Enter
The system responds:
SNR threshold set to : n
Where
n
is the current SNR threshold setting